Introduction
This document defines the supported HP NetServer LP2000r configurations using the HP Rack Storage/12FC
and Microsoft Cluster Server. These configurations minimize single points of failure (SPOF, SPOFless
provide extended availability. The specific configuration certified and supported by both Hewlett-Packard and
Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers. This
guide is prescriptive; it describes the configurations supported by HP. Any deviance to these configurations can
result in an inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and
therefore will not be supported by HP.
What's Defined in a Racked Cluster
Cluster
Type of SPUs
Number of nodes
Shared Storage
LANs:
Client LAN
1
For more information about configuring a SPOFless cluster, refer to the HP white paper, High Availability
MSCS Cluster Solution on the HP NetServers, HA Planning website.
HP NetServer LP2000r
with
HP Rack Storage/12FC
Windows 2000 Advanced Server
Cluster Configuration Guide
21 March 2001
(see
Versions
at the end of this document)
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
HP NetServer LP2000r
Each node must be the same SPU, but may have different clock speeds,
main memory sizes, cache sizes, and number of CPUs .
2
HP Rack Storage/12FC with 2 FCArray Cards, HP disks, and using an
HP D8602B HBA in each server. See
Any NIC that is HP and Microsoft approved. See
For a SPOFless cluster, two D5013B NICs configured with AFT is
recommended (Add one NIC and pair with embedded).
Shared Storage
1
1
) and
below.
Client LAN
below.