CIM Alerts

Table 16

CIM Alert indication events

FRU/Event category Corresponding SMI-S class Operational status values that would trigger alert
Controller
Hard Disk Drive
Fan
Power Supply
Temperature Sensor
Battery/Super Cap
FC Port
SAS Port
iSCSI Port
NOTE:
There is no support for Life Cycle indications in this release.

SMI-S configuration

In the default SMI-S configuration:
The SMI-S protocol is turned on.
The SMI-S interface is enabled for the manage user.
The following table lists the CLI commands relevant to the SMI-S protocol:
Action
Enable the SMI-S protocol
Disable the SMI-S protocol set protocols smis disabled
See the current status
To configure the SMI-S interface for other users:
1.
Log in as manage
2.
If the user does not already exist, create one using this command:
create user level manage username
3.
Type this command:
set user username interfaces wbi,cli,smis,ftp
146 Using SMI-S
HP_Controller
HP_DiskDrive
HP_PSUFan
HP_PSU
HP_OverallTempSensor
HP_SuperCap
HP_FCPort
HP_SASTargetPort
HP_ISCSIEthernetPort
CLI command
set protocols smis enabled
show protocols
conditions
Down, Not Installed, OK
Unknown, Missing, Error, Degraded, OK
Error, Stopped, OK
Unknown, Error, Other, Stressed, Degraded, OK
Unknown, Error, Other, Non-Recoverable Error, Degraded,
OK
Unknown, Error, OK
Stopped, OK
Stopped, OK
Stopped, OK