Overview
Read these instructions to set up and configure the HP
SN6000B 16Gb 48-port Fibre Channel Switch and
HP SN3000B 16Gb 24-port Fibre Channel Switch.
These instructions provide basic configuration steps.
For detailed rack mount and configuration instructions,
download the HP B-series 16Gb Switches Hardware
Reference Guide from the storage section of the HP
website: http://www.hp.com/support/manuals.
Figure 1 (page 1)
switch.
SN6000B 16Gb 48-port FC switch
Figure 1 Port side of the 48-port FC Switch
1. System status LED
2. Management Ethernet port
with LEDs
3. USB port
4. FC ports (0-3)
5. FC ports (40-43)
Verify the SN6000B 16Gb 48-port FC

switch carton contents

Verify that the carton contains the following (any SFPs
ordered will not be in this carton; they will be
packaged separately):
One HP SN6000B 16Gb 48-port FC Switch with
two integrated power supply/fan assemblies
Rubber feet, required to set up the switch as a
standalone unit
Serial cable with an RJ-45 connector plus an
adaptor for RJ-45 to DB9
HP SAN Network Advisor DVD
Brocade EZ Switch and China ROHS
documentation
Page 1
shows the port side of the 48-port
6. FC ports (44-47)
7. FC ports (4-7)
8. Switch ID pull-out tab
9. Serial console port
10. System power LED

Advertisement

Table of Contents
loading

Summary of Contents for HP SN3000B

  • Page 1: Quick Start Instructions

    Overview Read these instructions to set up and configure the HP SN6000B 16Gb 48-port Fibre Channel Switch and HP SN3000B 16Gb 24-port Fibre Channel Switch. These instructions provide basic configuration steps. For detailed rack mount and configuration instructions, download the HP B-series 16Gb Switches Hardware Reference Guide from the storage section of the HP website: http://www.hp.com/support/manuals.
  • Page 2 Verify that the carton contains the following (any SFPs supported transceivers. ordered will not be in this carton; they will be packaged separately): One HP SN3000B 16Gb 24-port FC Switch with one integrated power supply/fan assembly Plan the SN6000B and SN3000B 16Gb FC Switches site environment...
  • Page 3: Installing Using Rack Mount Kit

    Mount Kit of the rack. You can use the SN6000B and SN3000B Switch Rack Attach each rear mounting bracket to a rear rack Mount Kits to install your HP SN6000B and SN3000B upright column using two Phillips screws and 16Gb FC Switches in HP 10000 Series Racks.
  • Page 4 Attach each outer rail as shown in Figure 5 (page power supplies. Connect two power cords to the 48-port switch. Connect one power cord to the 24-port switch. See Figure 7 (page The rails are labeled Left and Right to designate the left side and right side of the rack as viewed IMPORTANT: Make sure that the power...
  • Page 5: Install A Standalone Switch

    “Verify the SN6000B 16Gb 48-port FC switch carton contents” (page 1) “Verify To set up the switch, you will need the following: the SN3000B 16Gb 24-port FC switch carton Standard screwdriver contents” (page If you are using static IP addressing, you will need...
  • Page 6: Log In To Serial Console Port

    Log in to the serial console port Remove the serial cable and replace the plug in the serial port. Verify that the switch has completed POST. Connect the Ethernet port on the switch to the When POST is complete, the port status, switch Ethernet network that assigned the IP address.
  • Page 7: Configure Zones/Perform Device Selection

    Enter the tsclockserver command to Install the SFP+ transceivers in the Fibre Channel synchronize local time using NTP: ports on the switch to match the ports shown on the screen (see Figure 8 (page 7)). If you are switch:admin> tsclockserver using an SFP+ transceiver that does not have a <ntp1;ntp2>”...
  • Page 8: Verify Switch Operation

    Set switch features This completes the initial setup of your HP SN6000B or SN3000B 16Gb FC Switch. See the HP StorageWorks Fabric OS 7.0.x Administrator's Guide and the Fabric OS 7.0.x Command Reference Manual for detailed instructions on setting all supported switch features.