Page 1
INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3023ST LRE3025SB LRE3023SB LRE3025SW LRE3023SW Printed on 100% Recycled Paper www.lg.com...
TABLE OF CONTENTS TABLE OF CONTENTS SAFETY 3 Before You Begin 3 Important Safety Instructions 5 Prepare to Install the Range PREPARE TO INSTALL RANGE 6 Installation Drawings ELECTRICAL CONNECTIONS 7 Electrical Connection Requirements 7 Connect Range Cord 8 3-Wire Connection With a Power Supply Cord 9 4-Wire Connection With a Power Supply Cord 9 3-Wire Connection: Conduit 1 0 4-Wire Connection: Conduit...
Remove all tape and packing materials before using the range. Dispose of all plastic bags after unpacking the range. Never allow children to play with packing materials. You can download the installation and owner’s manual at: http://www.lg.com. IMPORTANT SAFETY INSTRUCTIONS Read and follow all instructions before using your oven to prevent the risk of re, electric shock, personal injury, or damage when using the range.
Page 4
SAFETY WARNING • Power supply cord and plug should not be modi ed. If it will not t the outlet, have a proper outlet • Using an extension cord to connect the power is prohibited. The way to connect the power cord and plug directly is strongly recommended.
SAFETY PREPARE TO INSTALL THE RANGE WARNING • The information in this manual should be TOOLS NEEDED followed exactly. - A re or electrical shock may result causing property damage, personal injury or death. Phillips Screwdriver Level WARNING Flat-blade • Any person should not step or Adjustable Wrench Screwdriver sit on the oven door.
PREPARE TO INSTALL THE RANGE INSTALLATION DRAWINGS NOTE SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR CLEARANCES AND DIMENSIONS (Figure 1) To install range refer to the following Figure 1. For installation in CANADA, a Free-standing range is not to be installed closer than 15/32 (12mm) from any adjacent surface.
ELECTRICAL CONNECTIONS ELECTRICAL CONNECTION CONNECT RANGE CORD REQUIREMENTS The Rear Access cover must be removed. Loosen the three screws with a screwdriver. The terminal block will This appliance must be installed and grounded on a then be accessible. branch circuit by a quali ed technician in accordance with the National Electrical code ANSI/NFPA NO.
ELECTRICAL CONNECTIONS 3-WIRE CONNECTION WITH A POWER SUPPLY CORD WARNING • The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main Cord strain relief terminal block.
ELECTRICAL CONNECTIONS 4-WIRE CONNECTION WITH 3-WIRE CONNECTION: CONDUIT A POWER SUPPLY CORD Install the conduit as follows: WARNING Remove the Conduit connection plate from the rear of lower oven and rotate it as shown in Figure 5. The • Only a 4-conductor power-supply cord kit rated conduit hole (1 ") must be used.
ELECTRICAL CONNECTIONS 4-WIRE CONNECTION: CONDUIT 1. Follow the instructions under “Install the conduit as 4-wire connection follows” on page 8 to correctly install the strain relief. Black White Red DO NOT install the conduit without a strain relief. Terminal 2. Loosen the 2 lower left and right screws from the block terminal block.
INSTALL THE RANGE Replace the access cover on the back of the range. To replace the wire cover, insert the two tabs into the openings located below the opening and tighten the three screws. Lower range Access cover leveler Raise range Use a level to check your adjustments.
Page 13
LG Customer Information Center For inquires or comments, visit www.lg.com or call 1-800-243-0000 USA, Consumer User 1-888-542-2623 CANADA Register your product Online! Printed on 100% Recycled Paper www.lg.com Printed in Korea...