Chapter 3
Figure 3-7. Mounting Hardware for Front Bezel for Compaq Rack

Attaching the Cable Management Arm

The Cable Management Arm for the HP NetServer can only be mounted on HP
Systems racks. The HP NetServer Cable Management Arm allows the cables,
including the power cords, to move in and out with the HP NetServer chassis on its
slides without being accidentally disconnected (see Figure 3-8).
WARNING
Before sliding out the HP NetServer, ensure the anti-tip foot
from under the front of the rack is extended or the anti-tip
feature is installed. A tip-over hazard exists, so never slide
more than one component out of the rack at a time.
1. Ensure the HP NetServer is pushed all the way into the rack.
2. At the rear of the NetServer, place rack nuts on the left column in the 17th
and 18th holes above the baseline of the HP NetServer (see Figure 3-8).
Conversion: Install Components, Cover, and Front Bezel
Compaq
Rack
29