Server with netraid-3si (hp rack storage/12 and /8)
Hide thumbs Also See for D7171A - NetServer - LPr:

Advertisement

System software:
Navigator version
Operating System
Service pack
SPU
Model
Clock speed
No. of CPUs
BIOS version
CPU cache
RAM
No. of power supplies
Local storage
I/O slots:
Storage
Local
Controller and Cabinets
(physical drive location)
Disk drives (hot swap
or fixed)
SCSI bus
SCSI IDs
Shared
Controller
Model
No. of controllers
Firmware
BIOS
Driver
NetRAID Assistant
SPU I/O slot
SCSI ID
Channels
L.15.15 or later (350-450 MHz with 40 MB/Sec SCSI controller board)
L.16.00 or later (400 or 450 MHz with 80 MB/Sec SCSI controller board)
L.16.05 or later (500, 550, 600 MHz with 40 MB/Sec SCSI controller board)
Microsoft Windows NT Server 4.0, Enterprise Edition
SP4 or later
HP NetServer LH3
350, 400, 450 MHz with Rack Storage/12 D5989A
400, 450, 500, 550, 600 MHz with Rack Storage/12 D5989B
2
4.06.28PL or later (350-450 MHz with Rack Storage/12 D5989A)
4.06.14PL or later (400 or 450 MHz with Rack Storage/12 D5989B)
4.06.33PL or later (400, 450, 500, 550, 600 with Rack Storage/12 D5989B
Any size
128 MB minimum. Must be HP.
2 required, 3 for redundancy
Internal or external, using any controller except embedded RAID or a
NetRAID-3Si. Must use HP disks. See
P7 – P8 Shared storage controller
P1 – Intra-cluster (Heartbeat) LAN
P2 – Client LAN
All others – Any other plug-in cards.
May use Embedded SCSI, NetRAID 1, NetRAID-1Si or NetRAID 3 in
PCI slot P8 for internal storage or with a Rack Storage/8, otherwise any
controller listed on the HP Tested Products List.
May not use Embedded RAID or NeRAID-3Si for internal storage or
external with a Rack Storage/12.
HP only
Any HP cables that meet SCSI specifications and any SCSI bus speed.
Any
HP NetRAID-3Si Adapter D5955A
1
W.01.20
B.01.10
2.22
A.01.15 or later
P7 - P8
6, 7
0, 1, 2
2
Local Storage
below.