SPU
Model
Clock speed
No. of CPUs
BIOS version
CPU cache
RAM
No. of power supplies
Local storage
Storage
Local
Controller
Cabinets (Physical drive
location)
Disk drives (hot swap or
fixed)
SCSI bus
SCSI Ids
Shared
HP SureStore E Disk
Array FC60
Host Bus Adapter
Model
No. of HBAs
Driver
RAID level
Array Controller
Model
RAID arrays
Firmware
Disk Enclosures
Disk Encolsure
Model
Number of disks
HP NetServer LH 6000
550 Mhz
2-6
6.0.1
2 MB
2 GB. Must be HP.
3
See Local Storage below.
May Use - Embedded SCSI, NetRAID-1Si or NetRAID-3Si in PCI slot P1,
otherwise any controller listed on the HP Tested Products List.
May Not Use - NetRAID-1 or NetRAID-3
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Must be HP
Any HP cables that meet SCSI specifications and any SCSI bus speed.
Any
(Required)
HP D8602A
2
1.12
0, 1, 3, 5, or 0 & 1
A5635A HP SureStore E Disk Array FC60
Not more than 8 LUNs are permitted.
04.00.00.20 or later
Up to 6 per array controller
A5636A HP SureStore E Disk System SC10
4,5,6,7,8,9 or 10 per enclosure
2