GE PI6000 - Sentrol Motion Detector Installation Instructions page 3

6000 series pir

Advertisement

PI6000
Pet Immune Lens
40'
Top View
12.2m
30'
9.1m
20'
6.1m
10'
3.0m
0'
0'
7'
Side View
2.1m
(Center Beams)
0' 60
6000
High Density Lens
Top View
35'
10.1 m
16'
5 m
0
16'
5 m
35'
10.1 m
6.9'
Side View
2.1 m
Figure 5. Zone Patterns
PI6000 Lens Mask
Peel and stick groove side of lens
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
10'
20'
30'
40'
3.0m
6.0m
9.0m
12.2m
4
30
15
Floor Line
88.6
7'
13'
23'
35'
2 m
4 m
7.1 m
10.1 m
PI6000 Pet Immune
L
K
W
V
Masking
1.
Unsnap the shield from the front cover by grasping the edge of the
two tabs holding the shield in place and gently pulling the shield away
from the front housing. Remove the lens from the front housing.
Make sure fingers are clean.
2.
Identify the lettered zone on the mask that corresponds to the letter
on the lens.
3.
Peel off the masking strip and press it onto the corresponding grooved
segment on the lens.
4.
Reinstall the lens in the front housing. The notch on the lens matches
the notch on the front housing. (bottom right corner).
5.
Snap the shield assembly back into the front cover.
Maintaining the Detector
When installed and used properly, the detectors provide up to 5 years of
service with minimal maintenance. To ensure proper operation, walk test
the detector annually.
Clean the inside of the detector with a soft bristled brush or compressed
air. Clean the outside with a damp (water) cloth as needed to keep it free of
dust and dirt. Always test the detector after cleaning.