Cleaning The Strainer Insert; Flowrate Limiter - Electrolux ELECTRONIC BASIC IH 18 Instructions For Installation And Use Manual

Instantaneous water heater
Table of Contents

Advertisement

Cleaning the strainer insert

If the water flowrate is reduced by dirt from the cold water line, the strainer-
insert should be cleaned as follows:
1
Flow rate limiter
2
1
− Shut off cold water on shutoff unit (1)
− Loosen cap nut (2) using a spanner
− Take out and clean strainer (3)
− Re-assemble in reverse sequence
− Open cold water on shutoff unit (1); check
tightness
3
2
The flow rate limiter (2) is installed in the cold
water connector (1) to allow a constant outlet
temperature at high flow pressures of approx. 40° C,
suitable for showering.
(See table page 4 and 6)