Hitachi L300P Series Quick Reference Manual page 16

Three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

Error
Code
Inverter thermal trip
E21
Gate array error
E23
Phase failure detection
E24
IGBT error
E30
Thermistor
E35
Under-voltage (brownout)
––––
with output shutoff
Automatic restart and phase
loss
E6X
Expansion card #1 error
Expansion card #2 error
E7X
Error Status Codes and Error Trip Conditions
The digit to the right of the decimal point in the error code (such as
indicates inverter status at the moment the error occurred. Use the Up and
Down arrow keys to scroll through the trip condition parameters.
Status
Inverter
Code
Status
Reset
---.0
Stop
---.1
---.2
Deceleration
Constant
---.3
speed
---.4
Acceleration
Name
Status
Inverter
Code
f0 stop
---.5
Starting
---.6
---.7
DC braking
Overload
---.8
restriction
Probable Cause(s)
• Inverter internal temperature is above
the threshold
• An internal inverter error has occurred
(CPU / gate array IC)
• One of three lines of the 3-phase
power is missing
• Instantaneous over-current on any
IGBT (output transistor) device
• Thermistor input, [TH] and [CM1], is
over the temp. threshold
• Low input voltage caused the inverter
to turn OFF the motor output and try to
restart. If unsuccessful, a trip occurs.
• Inverter is restarting, due to an over-
current, over-voltage, under-voltage, or
a phase loss event.
• An error has occurred in an
expansion card or at its connecting
terminals. Please refer to the manual for
the expansion card for additional details.
Status
1
2
14
Trip Conditions
Error code
Output frequency
Motor current
DC bus voltage
Cumulative op. time
Cumulative ON time
E01.4
)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents