8-16-5. Detail Level Adjustment

Note
Perform this adjustment, if necessary, to suit the custom-
er's preferences.
Preparation
. On the setup menu, set as follows.
PAGE
: S12*FUNCTION 1/2
ITEM
: DETAIL
ITEM
: TEST OUT
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
: 1Lens IRIS
Setting point
Spec.
: A = 80 2 IRE (NTSC)
A = 560 14 mV (PAL)
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE
: S16*LEVEL 1
ITEM
: DETAIL LVL (Factory setting : 0)
Spec.
: Adjust to the detail amount which is added
to each step in the grayscale chart for the
customer's preferences.
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
ON
ENC
A

8-16-6. Knee Aperture Adjustment

Note
Perform this adjustment, if necessary, to suit the custom-
er's preferences.
Preparation
. On the setup menu, set as follows.
PAGE
: S12*FUNCTION 1/2
ITEM
: DETAIL
ITEM
: TEST OUT
PAGE
: S17*LEVEL 2
ITEM
: KNEE APT.
. OUTPUT/DCC switch (inside panel)
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment
: Waveform monitor
: 1 Lens IRIS
Setting point
Spec.
: A = 100
A = 700 14 mV (PAL)
. GAIN switch (inside panel)
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE
: S17*LEVEL 2
ITEM
: K.APT.LVL
Spec.
: Adjust the peak-to-peak level of the
noise at the third steps from the top
(portion B) in the grayscale chart, as
desired. (Reference level is 40 mV)
8-16. Detail Signal Adjustment
ON
ENC
ON
CAM/ON
2 IRE (NTSC)
A
M (9 dB)
B
8-21