HOW TO USE YOUR GENERATOR
If you have any problems operating your generator
after reading the manual, please call the generator
helpline at 1-800-222-3136.
System
Ground
The generator has a system ground that connects the
generator frame components to the ground terminals
on the AC output receptacles. The system ground is
connected to the AC neutral wire (the neutral is
bonded to the generator frame).
Special Requirements
There may be Federal or State Occupational Safety
and Health Administration
(OSHA) regulations, local
codes, or ordinances that apply to the intended use of
the generator. Please consult a qualified electrician,
electrical inspector, or the local agency having
jurisdiction.
In some areas, generators are required to be
registered with local utility companies.
If the generator is used at a construction site, there
may be additional regulations which must be
observed.
Connecting
to a Building's
ElectricaR
System
Connections for standby power to a building's
electrical system must be made by a qualified
electrician. The connection must isolate the generator
power from utility power, and must comply with all
applicable laws and electrical codes.
WARNING
When
using generator
for backup
power,
notify
utility
company.
Use approved
transfer
equipment
to isolate
generator
from electric
utility.
Use a ground
circuit
fault interrupter
(GFCI)
in any damp
or highly
conductive
area, such as metal
decking
or steel
work.
DO NOT touch
bare wires
or receptacles.
DO NOT use generator
with electrical
cords which
are
worn,
frayed,
bare or otherwise
damaged.
DO NOT operate
generator
in the rain.
DO NOT handle
generator
or electrical
cords while
standing
in water,
while
barefoot,
or while hands
or feet
are wet.
DO NOT allow unqualified
persons
or children
to operate
or service
generator.
Generator
Location
Generator Clearance
WARNING
Keep at least 5 ft. (152 cm) clearance
on all sides
of
generator
including
overhead.
Place generator in a well ventilated area, which will
allow for removal of deadly exhaust gas. DO NOT
place generator where exhaust gas could accumulate
and enter inside or be drawn into a potentially
occupied building. Ensure exhaust gas is kept away
from any windows, doors, ventilation intakes or other
openings that can allow exhaust gas to collect in a
confined area. Prevailing winds and air currents
should be taken into consideration when positioning
generator.
WARNING
Operate
generator
ONLY
outdoors.
Keep exhaust
gas from entering
a confined
area through
windows,
doors,
ventilation
intakes
or other
openings.
DO NOT operate
generator
inside
any building
or
enclosure
(even
if doors
or windows
are open),
including
the generator
compartment
of a recreational
vehicle
(RV).
Typical Generator
Shown
Exhaust Po_