GE 22 Owners And Installation Manual page 43

Profile side by side refrigerators
Table of Contents

Advertisement

Available languages

Available languages

Performance
Data Sheet
SmartWater Filtration System-GE ® MSWF Cartridge
This system has been tested and certified in filter model GE MSWFaccording to NSF/ANSI S tandards 42 and 53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration lessthan or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI S tandards 42 and 53.* (Safety factors built in for unmetered usage.)
Standard
No. 42: Aesthetic
effects
lnflue,t
Challenge
Parameter
'
USEPAMCL
I
Concentration
2.0 mg/L ± 10%
at least 10,000 particles/
mL
Standard
No. 53: Health
effects
influent Challenge
Parameter
Effluent
% Reduction
Average
Maximum
Average
'
Maximum
Min, Required Reduction
0.06 mg/L
0.10 mg/L
97%
9.1%
->50%
408,333
670.000
95.5%
89.4%
->85%
Effluent
'
% Reduction
'
Hax. Permissible
USEPAMCL
Concentration
Average
Maximum
Average
Maximum
1 NTU....
11 ± 1 NTU ....
0.38 NTU
0.5 NTU
96.5%
95.4%
99.95% Reduction
Minimum 50.000 L
< 1 #/L
4 #/L
> 99.99%
> 99.99%
0.010 mg/L
0.15 mg/L ± 10%
< 1 ppb
< 1 ppb
99.3%
99.3%
0.010 mg/L
0.15 mg/L ± 10%
3.1 ppb
9.0
ppb
98.0%
9s.s%
0.002 mg/L
0.006 mg/L ± 10%
0.34 ppb
0.7 ppb
94.0%
89.6%
0.002 mg/L
0.006 mg/L ± 10%
0.66 ppb
1.5 ppb
88.4%
73.7%
0.0002 mg/L
0.002 mg/L ± 10%
< 0.02 ppb
< 0.02 ppb
> 99.0%
> 99.0%
0.003 mg/L
0.009 mg/L ± 10%
< 0.5 ppb
< 0.0S ppb
> 93.9%
> 94.3%
0.070 mg/L
0.210 mg/L ± 10%
7.7 ppb
S5 ppb
96.0%
82.0%
0.003 mg/L
0.015 mg/L ± 10%
< 1 ppb
< 1 ppb
>92.9%
> 92.9%
0.005 mg/L
0.015 mg/L ± 10%
< 0.5 ppb
< 0.5 ppb
>96.8%
> 97.0%
0.040 mg/L
0.080 mg/L ± 10%
< 1 ppb
1 ppb
> 98.7%
> 98.7%
0.075 mg/L
0.225 mg/L ± 10%
< 0.S ppb
< 0.5 ppb
> 99.7%
> 99.8%
99% Reduction
107 tel0
8fibers/L;
<0.17 NF/L
<0.17 NF/L
>99%
>99%
ifibers > 10pm in length
"Testedusing pressure of 60 psig;pH of 7.5+ 0.5;temp of 68o+ S°F(20° + 2.5°C).
"'Measurement in Partides/mL Particles used were 0.5 1 microns.
""Based on the useof Cryptosporidium parvum oocysts.
.... NTU Nephelometric Turbidity Units
Product Water
0.5 NTU
99.95%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
99% Reduction
Capacity 300gallons (1.135liters). Contaminant reduction determined by NSFtesting.
Application
Guidelines/Water
Supply Parameters
ServiceFlow
WaterSupply
It isessentialthat the manufacturer'srecommended installation,maintenanceandfilter replacement r equirementsbe carriedout for the productto perform asadvertised.
Seeinsert for Warrantyinformation.
Operating
Specifications
• Pressurerequirement: 40 120 psi (2.8 8.2 bar),non shock
• Temperature: 33 100°F(0.6-38°C)
• Flow rate: 0.9 gpm (3.14Ipm)
General Installation/Operation/Maintenance
Requirements
• Flushnew cartridge at full flow for 4 1/2 gallons(aboutfive minutes)to purge
trapped air.
• Replacecartridge when flow becomes too slow.
, Protect from freezing by removing filter cartridge when temperatures are
expected to drop below 40°F (4.4°C).Do not install systems in areas where
ambient temperatures may go above IO0°F or below 40°E Do not install
on a hot watersupply.
Special Notices
Installation instructions are included with the product when shipped.
This drinking water system must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
• Do not use with water that is microbiologically unsafe or of unknown quality with
out adequate disinfection before or after the system. Systemscertified for cyst
reduction may be used on disinfected water that may contain filterable cysts,
• The contaminants
or other substances
removed or reduced by this water
treatment
system are not necessarily in your water.
Check for compliance
with the applicable
state and local laws and regulations.
Note that while the testing was performed
under standard laboratory
conditions.
actual performance
may vary. Systems must be installed and operated
in
accordance
with manufacturer's
recommended
procedures
and guidelines.
Installation
and use MUST comply with all state and local plumbing
codes. Do not
install if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi
(552 kPa).you should install a pressure
limiting valve. Contact a plumbing
professional
if you are uncertain
how to check your water pressure.
Do not install where water hammer conditions
may occur. If water hammer
conditions
exist you must install a water hammer arrester. Contact a plumbing
professional
if you are uncertain
how to check for this condition.
Where a backflow
prevention
device is installed on a water system, a device for
controlling
pressure due to thermal
expansion must be installed.
Forconditions of use, health claims certified by the California Department of Public
Health, and replacements, see performance data sheet. California Department
of Public Health Certification #06 1834.The contaminants or other substances
removed or reduced by this water filter are not necessarily in all users'water,
Tested and Certified by NSF International against ANSI/NSF Standards 42 and 53 in model GE P1SWF for the reduction of:
Standard No. 42: Aesthetic Effects
, Chemical
Chlorine Taste and Odor
.
Mechanical Filtration
Particulate Reduction. Class]
GE
Appliances
Appliance Park
Louisville, KY40225
geapplianceparts.com
Standard No. 53: Health Effects
, Chemical Reduction
Atrazine Reduction
Endrin Reduction
Benzene and Carbofuran Reduction
1,4 DicNorobenzene and
2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene
Reduction
, Mechanical Filtration
Cyst and Asbestos Reduction(_
REPLACEMENT
ELEMENT
EPA#20350-MN-005
© 2020 General Electric Company
PC61577C
43

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

2326272925Profile 22 ... Show all

Table of Contents