FOR YOUR SAFETY
READ BEFORE
OPERATING
WARNING:
mfyou
do not follow
these
instructions
exactly,
a fire or
explosion
may result
causing
property
damage,
personal
injury or ross of
life.
BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WiTH WATER AND AiR PURGED FROM ALL LINES.
A. This appliance
does not have a pilot. It is equipped
with
an ignition device which automatically
lights the burner.
Do NOT try to light the burner
by hand,
B. BEFORE OPERATmNG smell all around the appliance area
for gas. Be sure to smell next to the floor because
some
gas is heavier than air and will settle on the floor.
WHAT TO DO iF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch;
Do not use any phone in your building.
Immediately cell your gas supplierfrom
a neighbor's phone.
Follow the gas supplier's
instructions.
If you cannot
reach
your
gas supplier,
call the fire
department.
C. Use only your hand to push in the gas control buttons.
Never use tools. If the control buttons will not push in,
don't try to repair them, call a qualified service technician.
Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance
if any part has been under
water, immediately
contact a qualified installer or service
agency to replace a flooded water heater. Do not attempt
to repair the unit! It must be replaced!
OPERATING iNSTRUCTiONS
4. This appliance
is equipped
with
a device
which
automatically
lights the burner.
DO NOT TRY TO UGHT THE BURNER BY HAND.
1. f_
STOP!
Read the safety information
above,
on this label.
2. Set the thermostat
to the lowest setting by first pressing
the COOLER
_
and HOTTER,{__ buttons together and
holding for ! second. Then press the COOLER {_::)button
until the WARM indicator light appears.
3. Set the "ON/OFF"
switch on the blower control box to the
"OFF" position.
5. Wait five (5) minutes
to clear
out any gas.
If you then smell _
STOP!
Follow "B" in the
safety
his label. If you don't smell
gas, go to the next step.
6. Turn on all electrical power to the appliance.
7. Set thermostat
to desired setting by first pressing
the
COOLER {-\-}')and HOTTER j_}-_ buttons together and
holding
for 1 second.
Then press the HOTTER
([:3
button.
8. If the appliance will not operate, follow the instructions
"TO TURN OFF GAS TO APPLIANCE"
and call your
technician
or gas supplier.
9. WATERTEMPERATUREADJUSTMENT
V is approximately
120°F.
CAUTION:
Hotter
water
increases
the risk
of scald
injury.
Consult
the
instruction
manual
before
changing
temperature.
WARNmNG:TURN OFF ALL ELECTRIC
POWERBEFORESERVICING
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to the lowest setting by first pressing the COOLER _:_!,and HOTTER _
buttons together and holding
for 1 second. Then press the COOLER
{_
button until the WARM indicator light appears.
2. Set the ON/OFF switch on the blower control box to the "OFF" position.
3. Turn off all electric power to the appliance
if service is to be performed.