Thank You for p urchasing
aKenmore
water heater. Properly
installed
and maintained,
itshould give you years oftrouble free service, ifyou
should d ecide t hatyouwant t henew water h eater professionally
installed
by Sears call 1-8004-M%HOME®.
They \,viii arrange
for p rompt,
quality installation
by Sears authorized
contractors.
Abbreviations
Found In This Instruction
Manual:
CSA- Canadian
Standards
Association
ANSI
-American
National Standards institute
NFPA- National Fire Protection Association
ASME - American
Society of Mechanical
Engineers
GAMA - Gas Appliance
Manufacturer's
Association
UL - Underwriters
Laboratories
Inc.
This gas-fired water heater is listed by Underwriters
Laboratories
Inc.
underAmerican
National Standard/CSA Standard for Gas Water Heaters
ANSI Z21.10.1
• CSA4.!
(current edition).
PREPARING FOR THE INSTALLATION
Read the "Safety
Precautions"
section, page 3 of this manual first
and then the entire manual carefully.
If you don't follow the safety
rules, the water heater will not operate
properly.
It could cause
DEATH, SERIOUS BODILY INJURYAND/OR
PROPERTY DAMAGE.
This manual contains instructions
for the installation,
operation, and
maintenance
of the gas4ired water heater. It also contains warnings
throughout
the manual that you must read and be aware of. All
warnings
and all instructions
are essential
to the proper operation
of the water heater and your safety. Since we cannot put eveQ/thing
on the first few pages, READ THE ENTIRE MANUAL
BEFORE
ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
The installation
must conform with these instructions
and the Ioca!
code authority
having iurisdiction.
In the absence
of local codes,
installations shall comply with the National Fuel Gas COdeANSI Z223.1/
NFPA54 and the National Electrical Code, NFPA70. These publications
are available
from The National
Fire Protection
Association,
1
Battery, march Park, Quincy, MA 02269.
3. The water heater when installed must be grounded
in accordance
with the local codes, or in the absence
of local codes, the National
Electrical Code NFPA 70.
4. If after reading
this manual
you have any questions
or do not
understand
any portion of the instructions,
call the local gas utility or
the Sears Service Center.
Carefully plan the place where you are going to put the water heater.
Correct
combustion,
vent action, and vent pipe installation are very
important
in preventing
death
from possible
carbon
monoxide
poisoning
and fires.
Examine the location to ensure the water heater complies
with the
"Facts to ConsiderAbout
the Location" section in this manual.
For California installation this water heater must be braced, anchored,
or strapped
to avoid falling or moving during an earthquake.
See
instructions for correct installation
procedures.
Instructions may be
obtained from California
Office of the State Architect, 400 P Street,
Sacramento,
CA 95814.
7. Massachusetts
Code requires
this water heater to be installed in
accordance with Massachusetts 248-CMR 2.00: State Plumbing Code
and 248-CMR 5.00.
8. CompiieswithSCAQMDrule#1121
and distdcts having equivalent
NOx requirements.
MODEL
NUMBER
153.332040
153.332050
153.332060
153.332070
TANK
CAPACITY
IN GALS.
(LTRS)
40 (151)
50 (169)
40 (151)
50 (16e)
TYPE OF
GAS
NATURAL
NATURAL
PROPANE
PROPANE
INPUT
RATE
(Btuthr)
40,000
40,000
40,000
40,000
RECOVERY
RATE GALS.
PERHOUR
@90°F R_SE
44
44
44
44
MINIMUM
VENT PRPE
INCHES
(ram)
2 (51)
2 (51)
2 (51)
2 (51)
DBA_,_ETER
iNCHES
(ram)
18 1/2 (470)
20 (508)
18 1/2 (470)
20 (508)
DIMENSBONS IN
iNCHES (ram} NERGHT
TO JACKET TOP
55 (1,397)
56 3/4 (1,441)
55 (1,397)
56 3/4 (1,441)

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.332060153.332050153.332040Economizer 6