Mobile Home - Additional
Installation
Requirements
This laundry center is suitable for mobile home installations.
The installation must conform to the Canadian Manufactured
Home Standard, CAN/CSA-Z240
MH.
Mobile home installations
require:
Metal exhaust system hardware, which is available for
purchase from your local Sears store or Sears Service Center.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
The laundry center can be installed using the standpipe drain
system (floor or wall), the laundry tub drain system, or the floor
drain system. Select the drain hose installation method you need.
See "Alternate Parts."
Standpipe
drain system - wall or floor (views A & B)
The standpipe drain requires a minimum diameter standpipe of
2" (5 cm). The minimum carry-away capacity can be no less than
17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm)
diameter standpipe adapter kit is available. See "Alternate Parts."
The top of the standpipe must be at least 39" (99 cm) high and no
higher than 96" (2.4 m) from the bottom of the washer.
Electricam Shock Hazard
Pmug into a grounded
4 prong outBet.
Failure to do so can resumt in death or eiectdcam shock.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance
with the Canadian Electrical Code, C22.1 -latest
edition and local codes. A copy of the above codes standard
may be obtained from: Canadian Standards Association,
178
Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 115/230 volt,
60 Hz., AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended.
Connect to an individual
branch circuit.
This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure
wall receptacle is within reach of dryer's final location.
A
B
Laundry
tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top
of the laundry tub must be at least 34" (86.4 cm) above the floor
and no higher than 96" (2.4 m) from the bottom of the washer.
Floor drain system (view D)
The floor drain system requires a siphon break that may be
purchased separately. See "Alternate Parts."
The siphon break must be a minimum of 28" (71 cm) from the
bottom of the washer. Additional hoses might be needed.
D
4-wire receptacle
14-30R
Do not use an extension cord.
If using a replacement power supply cord, it is recommended
that you use Power Supply Cord Replacement
Part Number
9831317. For further information, please call 1-800-4-MY-HOMI::®
1-800-469-4663).
GROUNDING
INSTRUCTmONS
[]
For a grounded, cord-connected
washer/dryer:
This washer/dryer
must be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of Ieast resistance for
electric current. This washer/dryer
is equipped with a cord
having an equipment-grounding
conductor and a grounding
plug. The pIug must be plugged into an appropriate outlet
that is properly installed and grounded in accordance with
all local codes and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the washer/dryer
is properly grounded. Do not modify the plug provided with
the washer/dryer:
if it will not fit the outlet, have a proper
outlet instaIled by a qualified electrician.
SAVE THESE
INSTRUCTIONS