Frigidaire FH30DD50MSA Installation And Use & Care Manual

Telescoping downdraft ventilation system

Advertisement

Quick Links

TABLE
OF CONTEI'
Welcome & Congratulations
...................................
2
Installation
.........
Product Dimensions ...............................................
5
MajO_Appliance _rran_
....................................
16
Planning ...............................................................
6
www.frigidaire.com
USA 1-800-944-9044
www.frigidaire.ca
Canada 1-800-265-8352

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FH30DD50MSA

  • Page 1 TABLE OF CONTEI' Welcome & Congratulations ........Installation ..Product Dimensions ..........MajO_Appliance _rran_ ........Planning ............... www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352...
  • Page 2 Congratulations on your purchase of a new appliance! At Product Registration Electrolux Home Products, we are very proud of our product and are completely committed to providing you Register Your Product The PRODUCT with the best service possible. Your satisfaction is our number one priority.
  • Page 3 Read all instructions before using this appliance, Save these instructions for future reference, TO REDUCE THE RISK OF A RANGE TOP GREASE DEFINITIONS FIRE: Thisis the safety alert symbol.Itisused to alert • Never leave surface units unattended at high you to potential personal injury hazards. Obey all safety settings.
  • Page 4: Tools You Will Need

    Stabilizing Brackets Instruction Manual Cutout Template Warranty Card Telescoping Downdraft Duct Transition Tools You Will Need Phillips Screwdriver Retain packing materials until telescoping downdraft and all components have 1/4" Nut Driver / Ratchet been installed, - Tape Measure Hardware (User Supplied) Carpenter Square (4) Screws appropriate for - Vertical Level or Plum Line...
  • Page 5: Cutout Dimensions

    Downdraft Top Trim Rise 17/16 (3.6 2 1/4H (5.7 11 7/S (29.o ® FH30DD50M5 30" (76.2 cm) 26 Vs" (68.3 cm) 17 13/15' 34 5/!6" 2 3/!6" 10" (25.4 cm) FH36DD50MS 36" (91.4 cm) 32 7/8" (83.6 cm) (45.2 cm) (87.2 cm) (5.5 cm) Cutout Dimensions...
  • Page 6: Basic Information

    Take Heasurements Basic :Information A qualified technician must complete the installation of this Refer to the cooktop installation instructionsfor dimensions appliance. This downdraft blower system is designed to be of the cooktop, countertop cut-out and cabinet requirements. It is recommended that oversized cabinets be used for easier used to exhaust airborne contaminants when cooking with installation.
  • Page 7: Plan The Ductwork

    Plan the Ductwork This downdraft blower system is designed for use with 31/4 x 10" ductwork (can be transitioned to 6" round). For best performance, choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. The system will operate most efficiently when the ductwork does not exceed 60 feet of equivalent duct.
  • Page 8 Plan the Electrical Connection The downdraft blower system draws 2.8 AMPS and requires a 120 VAC, 60 Hz circuit. If the 30" model is being installed in a 30" wide cabinet The unit has a 28 inches long power cord with a 3 pronged or the 36"...
  • Page 9 1. Cut Countertop Opening 3. Prepare the Downdraft Blower System Duct Connection - Lay out and cut the cooktop cut-out far enough forward so downdraft will fit behind it (refer to cooktop installation The downdraft is shipped with blower oriented for exhaust instructions).
  • Page 10: Mount The Unit

    4. Install Duct Transition to Blower of the cabinet so that the vent chassis housing is vertical, check the level of the vent on both the right and left sides, Install the duct transition on the blower, using the three and tighten the screws, wide head Phillips screws.
  • Page 11: Install Ductwork

    6. Install Ductwork - Use galvanized or aluminum duct in 6" round or 3 1/4"x 10" size, or a combination of both. PVCduct should be used if installing under a poured concrete slab. Use the shortest and straightest duct run possible. The system will operate most efficiently when the ductwork does not exceed 60 feet of equivalent duct.
  • Page 12 Calculating Duct Length Table For maximum efficiency, use the shortest and straightest duct possible. The system will operate most efficiently when the ductwork does not exceed 60 feet of equivalent duct. The downdraft will operate properly with ductwork up to 100 equivalent feet of duct.
  • Page 13 Operating the Telescoping - The blower can also be turned off by simply pressing the raise/lower push button and lowering the telescoping Downdraft System vent. Raise the downdraft by pressing the raise/lower push button. The telescoping vent will rise up to full height. - The blower can then be turned on by sliding the control knob up.
  • Page 14 Cleaning the Telescoping Downdraft Vent Cleaning of the Telescoping Vent - Clean the stainless steel and plastic controls with a dishcloth and hot soapy water. It is advised to disconnect power from the downdraft when - Rinse with a dishcloth and clean water. cleaning to minimize risk of electrical shock or damaging theapp !ance due tosp!"s o nto e ectr ca components:...
  • Page 15 Beforeyou call for service, review this list. It may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this appliance. Telescoping Vent Check for and remove obstructions. The telescoping vent is designed to tilt and stop with does not fully raise obstructions.
  • Page 16 Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions.