Menu Setting Mode - Panasonic DP-100 series Instruction Manual

High-performance digital display
Hide thumbs Also See for DP-100 series:

Advertisement

High-function type
<Setting condition 7>
Comparative output 1 output mode: '
Analog voltage output / external input selection: '
<Setting condition 8>
Comparative output 1 output mode: '
Analog voltage output / external input selection: '
Automatic
MODE
Blinks alternately
<Setting condition 9>
Comparative output 1 output mode: '
Analog voltage output / external input selection: '
Automatic
MODE
Automatic
<Setting condition 10>
Comparative output 1 output mode: '
Analog voltage output / external input selection: '
Automatic
MODE
Automatic
MODE
MODE
Blinks alternately
Note: Auto-reference value and remote zero-adjustment value are displayed.
For details, refer to '
AUTO-REFERENCE FUNCTION ' and '
12
ZERO-ADJUSTMENT FUNCTION '.
Common
Zero-adjustment function
The zero-adjustment function forcibly sets the pressure value to 'zero'
when the pressure port is opened.
Key lock function
The key lock function prevents key operations so that the conditions set
in each setting mode are not inadvertently changed.
<Key lock set>
MODE
<Key lock released>
MODE
Peak / bottom hold function
The peak / bottom hold functions display the peak value and bottom val-
ue of the fluctuating pressure.
The peak value is displayed on the main display and the bottom value is
displayed on the sub-display
<Peak / bottom hold set>
Hold
MODE
down
<Peak / bottom hold released>
Blinks alternately
' (EASY mode)
' (Analog voltage output)
<RUN mode state>
' (EASY mode)
' (Auto-reference input) or
'
' (Remote zero-adjustment input)
<RUN mode state>
(Note)
' (Hysteresis mode) or
'
' (Window comparator mode)
' (Analog voltage output)
<RUN mode state>
' (Hysteresis mode) or
'
' (Window comparator mode)
' (Auto-reference input) or
'
' (Remote zero-adjustment input)
<RUN mode state>
(Note)
Hold
down
Automatic
(Key lock set)
Hold
down
Automatic
(Key lock released)
Hold
down
Automatic
.
Blinks alternately
Hold
down
MODE
9

MENU SETTING MODE

When the mode selection key is held down for two seconds in the
RUN mode, the menu setting mode will open.
The mode will change to the RUN mode when the mode selection key
is held down during this setting process.
The leftmost setting items are the default settings (factory settings).
<RUN mode>
<Comparative output 1 output mode setting>
(EASY mode)
Standard type
<Comparative output 2 output mode setting> (Note 1)
(OFF mode)
High-function type
<Analog voltage output / external input selection>
Analog
voltage
output
Standard type
<N.O. / N.C. selection> (Note 1) (Note 2)
Output 1: N.O.
Output 2: N.O.
High-function type
<N.O. / N.C. selection> (Note 2)
(N.O.)
REMOTE
13
<Response time setting>
(2.5ms)
<Display color of the main display selection>
Red when ON
Green when OFF
MPa (Note 3)
<RUN mode>
Notes: 1)
If the comparative output 2 output mode setting is set to '
N.O. / N.C. selection is the same as the high-function type.
2)
The default setting of the high pressure type is '
3)
The default setting of the low pressure type is '
4)
This is not displayed on the high-pressure type.
Setting item
Comparative output 1
output mode setting
Comparative output 2
output mode setting
(Standard type only)
Analog voltage output /
external input selection
(High-function type only)
N.O. / N.C. selection
Response time setting
Displayed color of the
main display selection
Unit selection
Press for 2 sec.
MODE
Hysteresis
mode
MODE
(EASY mode)
Auto-refer-
ence input
MODE
Output 1: N.C.
Output 2: N.C.
(N.C.)
MODE
(5ms)
MODE
Red when ON
(Always red)
Green when OFF
MODE
(kPa)
(kgf/cm
MODE
(inchHg) (Note 4)
(mmHg) (Note 4)
Description
Sets the output operation of comparative output 1.
Sets the output operation of comparative output 2.
Selects analog voltage output, auto-reference input, or remote zero-ad-
justment input.
Normal open (N.O.) or normal close (N.C.) can be selected.
Sets the response time.
The response time can be selected from 2.5ms, 5ms, 10ms, 25ms, 50ms,
100ms, 250ms, 500ms, 1,000ms or 5,000ms.
Displayed color of the main indicator can be changed.
Pressure unit can be changed.
Window
comparator
mode
Hysteresis
Window
mode
comparator
mode
Remote
zero-adjust-
ment input
Output 1: N.O.
Output 1: N.C.
Output 2: N.C.
Output 2: N.O.
(5,000ms)
(Always green)
(bar)
2
)
(psi)
', the display of
', and that of the low pressure type is '
'. '
' is not displayed.
'.