Electrical Requirements - KitchenAid KBZU122VSS Installation Instructions And Use & Care Manual

Outdoor built-in dual side burners installation instructions
Table of Contents

Advertisement

Available languages

Available languages

I _%(*a_HH_
_?_:__H_"__'_
_!C
Select alocation t hatprovides minimum exposure towind and
traffic paths. The location s hould beaway from strong draft
areas.
Donotobstruct flowofcombustion and ventilation air.
Clearance tocombustible
construction forbuilt-in outdoor side
burners:
• Aminimum of24"(58 cm)must b emaintained between the
sides andback andanycombustible construction.
• Azero clearance may bemaintained below thecooking
surface a ndanycombustible construction.
Ignition
A grounded, 3-prong outdoor GFI outlet is to be located inside
the island cabinet and to the left of the side burner. See
"Electrical Requirements"
section.
Style 1 - Front to Back Built-In
Dual Side Burners
7-
B
i
A
©
©
E
F
G
A. 13" (33 cm)
B. 10%" (27 cm)
C. 17" (43.2 cm)
D. 26%" (67 cm)
E. 253/8" (64.5 cm)
F. Manifold pipe
G. 4%" (11.1 cm)
H. 223/4'' (57.8 cm)
Style 2 - Side by Side Built-In Dual Side Burners
T
B
i
L
©
©
<
C
E_
r"
F
f
A. 24" (61 cm)
B. 10%" (27 em)
C. 28" (71.1em)
D. 201/_" (52.1 em)
E. 191/_" ( 49.5 em)
F. Manifold pipe
G. 43/8"(11.1 cm)
H. 17" (43.2 cm)
Built-In Outdoor Side Burner Enclosure
This built-in outdoor side burner is for installation in a built-in
enclosure constructed
of combustible
and non-combustible
materials. Some types of non-combustible
materials could be
brick, firewall or steel. Some types of combustible
materials
could be wood or laminate.
The enclosure for the built-in outdoor side burner is to be a
minimum of 11" (28.0 cm) high x 23" (58.4 cm) deep x
14" (35.6 cm) wide for front to back model and 11" (28.0 cm)
high x 17" (43.2 cm) deep x 25" (63.5 cm) wide for side by side
model.
Counter or support surfaces must be level.
The installation of this side burner must conform with local codes
or, in the absence of local codes, with either the National Fuel
Gas Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane
Installation Code, CSA B149.1, or Propane Storage and Handling
Code, B149.2.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
NOTE: The outdoor side burner drops into the enclosure opening
and is supported
by its side flanges. No bottom support is
needed.
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kbzu242vssKbzu122tssKbzu242tss

Table of Contents