Download Print this page

Pioneer PRO-510HD Service Manual page 3

Projection monitor receiver
Hide thumbs Also See for PRO-510HD:

Advertisement

6. ADJUSTMENT
6.1 INTRODUCTION
• IMPORTANT
When replacement of the following assemblies are required during repairs, be sure to replace the EEPROMs with the mounted ones in order to
retain the adjustment data of the unit and to facilitate adjustment after the replacement of the assemblies.
Name of Assy
SIGNAL Assy
IC2454 [24LC32(I)P]
DIGITAL CONV. Assy
IC1410 [24LC128P]
IC1656 [24LC08B(I)P]
Notes:
• Even if the EEPROMs are replaced, adjustment may be necessary, depending on the part or assembly to be replaced.
For details, see page 197.
• Even if the EEPROMs are replaced, if the EEPROMs are damaged or if their data have been changed from the adjustment data, the status
before the failure will not be restored. Check the status of the unit after replacement of the EEPROMs, and readjust if necessary.
6.2 JIGS AND MEASURING INSTRUMENTS
Remote control unit
AXD1448 (CU-SD110)
(For PRO-610HD, PRO-510HD)
Color bar generator
Dual-trace oscilloscope
PRO-610HD, PRO-510HD, SD-582HD5, SD-532HD5
EEPROM
Adjustment data, such as W/B and color data, in FACTORY mode
User data set on the MENU
Convergence adjustment data
Convergence offset data
Remote control unit
AXD1449 (CU-SD111)
(For SD-582HD5, SD-532HD5)
D. DC Voltmeter
Frequency counter
Main Contents of Memory
Screwdriver
LD Player
For HD Signal generator
Adjustment screwdriver
Monoscope
195

Advertisement

loading

This manual is also suitable for:

Pro-610hdSd-582hd5Sd-532hd5