Edit the /etc/sysconfig/boot file and change RUN_PARALLEL="yes" to
o
RUN_PARALLEL="no" to remove parallel script execution.
-or-
Edit the /etc/init.d/.depend.start file and add DevMan: network at the end of the
o
file to add parallel information for DevMan.

Reconfiguring the agent on Linux operating systems

To configure the management module IP address or serial path for Red Hat Linux, run
/etc/rc.d/init.d/DevMan setup.
To configure the management module IP address or serial path for SUSE Linux Enterprise Server, run
/etc/init.d/DevMan setup.

Installing the agent on HP-UX operating systems

The UPS Power Protection Agent can be installed using an installation script, SAM, or silent installation
option on any supported HP-UX operating system.
IMPORTANT:
see "UPS Power Protection Agent requirements
requirements" on page 8)."
Installing the agent locally or remotely using the Installation
Script method
The agent can be installed two ways:
1.
If installing the software from the HP Infrastructure Management Pack CD, insert the CD into the
o
CD-ROM drive of the computer. From the console or a terminal window, go to the HP UPS Power
Protection Agent/...HP-UX/Agent subdirectory. Execute the following installation script:
./SetupRA
If downloading the software from the HP website (http://www.hp.com/go/rackandpower),
o
follow the instructions on the website to unpack the files. Locate the installation script (SetupRA).
Execute the following script:
./SetupRA
The script installs the agent and requests information to configure the application. Default values or
valid options are shown in brackets following each prompt.
To accept the EULA, enter yes.
2.
The script displays: Please enter a server to allow connections from.
Enter the IP address of the management module or the path to the serial device. This configuration
3.
ensures that only that particular management module executes commands and operating system
shutdowns on the computer running the agent.
The script displays: Please enter a second server to allow connections from.
Enter the IP address of a second management module or the path to the second serial device for
4.
redundant communication.
To ensure your system has the minimum requirements needed to run the agent,
("HP UPS Power Protection Agent
Installing the HP UPS Power Protection Agent 38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ups management module

Table of Contents