About command code table

RS-232C settings

Settings related to communication of this unit are made in the <System Menu>
Make the same settings as the connected modem or PC connected.
When remotely controlling this unit from a PC, set "Communication Mode" in the <RS-232C Setting> to "Remote
A," "Remote B," or "Remote C."
"Remote A" : Every status information is returned from the unit.
"Remote B" : Status information for the command is returned from the unit.
"Remote C" : Status information is not returned from the unit.
Available settings on the unit
Synchronization
1
Transmission rate for
receiving/sending data
2
Data bit length
3
Parity bit setting
4
Stop bit length
5
Line feed setting

Command code system

2 types of command codes of [direct operation specification] and [quasi-front panel operation] can be selected according
to the purpose of the unit operation.

Description of command code systems

Direct operation specification

This system controls or sets the unit by confirming the status from the unit such as execution or error which is responded
to the command from the personal computer. This command type is constructed by the "operation setting commands"
which sets operations, "menu setting commands" which directly sets various menus, and "status check commands"
which checks the operational status of the unit.
Input format
In case of "operation setting commands" and "status check commands," send the command to the unit for each opera-
tion such as power on/off, record, playback, etc.
In case of "menu setting commands," specify the setting item for each menu setting of the unit.
As a general rule, do not send commands continuously, but send the next command after checking that the present
command has been executed and completed.
Response format
After sending a command, the following items can be checked by the status returned from the unit.
1) Command execution result, error type, command name, and operation status.
2) For operation setting commands, the operational mode of the unit can be distinguished by the mode number of
the returned status.
Distinction cannot be made for menu setting type commands. (Mode number is notified only when the status is
changed.)
Example) Turning on the power of the Unit.
Replied status code
Command
from unit to PC
from PC
PW1
#1
#2
RC
EX,00PW1,04 #2
When the unit cannot execute the operation setting command or menu setting command sent from a PC, the error
type which shows the content of the error is returned from the unit. Check the error code and take appropriate
measures.
For operation setting commands such as recording, playback, etc., the interval between command transmission
and the actual operation (command execution) may take some time. To prevent the gap between operation and
actual execution, read the status after sending the command and check the actual operational transition, and then
send the next command.
While displaying the menu screen, you cannot change the menu setting by using menu setting command form.
Name on Menu
Asynchronous
Transmission
1200/2400/4800/
Mode
9600/19200
Data Bit Length
8 bit/7 bit
Parity Bit
None/Odd/Even
Stop Bit Length
1 bit/2 bit
Delimiter
CR/CR•LF
Indicates POWER ON command has been sent.
Indicates that the unit has received a command.
EX
: Indicates that a command has been executed.
00
: Indicates that the execution was successful. (Error type)
PW1 : Indicates response to POWER ON command.
04
: Indicates POWER ON status.
<COM/LAN>
Make the following settings on the PC
Synchronization
1
X control
2
S parameter
3
CS-RS hand-shake
Meaning
3
<RS-232C Setting>.
Screen display
Not available
Not available
Available

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx-tl5000u seriesDx-tl5000e series

Table of Contents