Alert Message
File server failed multiple times. Entering Maintenance
mode.
Insufficient disk space exists.
Unable to detect filesystem type on the Data volume.
Unable to detect filesystem type on the Namespace
volume.
Filesystem scan discovered inconsistencies.
Replication peer network disconnected.
NVRAM does not match the data volume.
Storage usage is approaching the system capacity.
Replication resync cannot proceed.
Out of space on replication target.
The filesystem has reached the maximum allowable limit
for files and directories. Creating new files and
directories will be denied.
System Chassis Alerts
number > detected a failure.
Power Supply <
number > is missing or has been removed.
Power Supply <
Description/Meaning or Action
Contact Dell Support for possible support assistance or
intervention.
The filesystem is now read-only.
Contact Dell Support for possible support assistance or
intervention.
Contact Dell Support for possible support assistance or
intervention.
Please check the filesystem report, and perform the
suggested action. Contact Dell Support for possible
assistance or intervention.
Check access to remote site.
If this is a newly replaced NVRAM, use the maintenance --
hardware --reinit_nvram command to reinitialize the
NVRAM.
For more information, see the
Command Line Reference Guide .
Clean up the filesystem. If issue persists, contact Dell
Support for possible assistance or intervention.
Namespace limit has reached its maximum.
Clean up the filesystem. If issue persists, contact Dell
Support for possible assistance or intervention.
Clean up the filesystem. If issue persists, contact Dell
Support for possible assistance or intervention.
Reconnect the power cable to the designated
power supply unit if it is disconnected.
Ensure that there is input AC power at the power
cable.
Use a different power cord.
If this does not resolve the issue, replace the designated
power supply.
The power supply might not be making a proper
connection.
Try reseating the power supply in the power
supply slot.
Reconnect the power cable to the designated
power supply unit if it is disconnected.
Ensure that there is input AC at the power cable.
Use a different power cord.