Specifications
Physical
Width:
Depth:
Height:
Weight:
Electrical
The switch automatically adjusts to any voltage between 100-240 volts and
either 50 or 60 Hz.
AC voltage:
Maximum current:
Frequency range:
Environmental
Temperature:
Relative humidity:
(non-condensing)
Maximum altitude:
1 If you are installing either of the Series 6400cl Switch devices using one of the fiber
44.3 cm (17.4 in)
43.0 cm (16.9 in)
4.4 cm (1.7 in)
6400cl (J8433A)
5.6 kg (12.35 lbs)
6410cl (J8474A)
6.15 kg (13.56 lbs)
100-240 volts
3.0A/1.5A
50/60 Hz
Operating
0°C to 55°C (32°F to 131°F)
15% to 95% at 40°C (104°F)
4.6 km (15,000 ft)
transceivers, the operating ambient temperature should not exceed 40°C (104°F). See
transceiver specifications in the ProCurve Switch cl Modules Installation Guide.
Non-Operating
1
-40°C to 70°C (-40°F to 158°F)
15% to 90% at 65°C (149°F)
4.6 km (15,000 ft)
A
A-1