Download Print this page

GE 8566267 Installation Instructions Manual page 10

24" (61 cm) gas washer/dryer

Advertisement

Optional exhaust installations
This washer/dryer
can be converted to exhaust out the right or left
side. To convert the washer/dryer, use Side Exhaust Kit
Part Number 279823. If your washer/dryer was previously
exhausted from the right or left side, it can be converted to rear
exhaust by using standard offset connections. To cover the hole in
the side, one of the following plugs can be added:
692790 (white)
3977784 (biscuit)
Follow the instructions in the kit to install. Kits are available from
the dealer from whom you purchased your washer/dryer.
A
B
A. Standard rear offset exhaust installation
C
B. Rear exhaust for offset close clearance connection
C. Left or right side exhaust installation
Alternate
installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Three close-clearance
installations are shown.
Refer to the manufacturer's instructions
provided with the vent
system.
j[
......
,
t ......
i
o
-
I
"'_q
i
/
/"
J'r
.......
,
......
"xi
.........
A
A. Loop system with standard elbows
B. Loop system with one offset & one standard elbow
C. Vent system with one periscope
(2" [5 cm] clearance)
NOTE: The following kits for close clearance alternate installations
are available for purchase. For ordering information, please refer
to your Use and Care Guide.
Over thetop
Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch
Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number 4396014 - 29" (73.66 cm)to 50" (127 cm)
mismatch
Special
provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine
vent length
1. Select the route that will provide the straightest and most
direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. When using elbows or making
turns, allow as much room as possible. Bend vent gradually to
avoid kinking. Avoid 90 ° turns when possible.
better
2. Determine vent length.
The maximum length of the exhaust system depends upon:
The type of vent (rigid metal or flexible metal).
The number of elbows used.
Type of hood.
Recommended
hood styles are shown here.
_
(1_'9"!m)
(10_2 era)
A. Louvered hood style
B. Box hood style
The angled hood style (shown following) is acceptable.
(6_4 era)
See the exhaust vent length chart that matches your hood
type for the maximum vent lengths you can use.
Exhaust systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance,
resulting in longer drying times and
increased energy usage.
10