Download Print this page

GE 8557471A Installation Instructions Manual page 6

24" (61 cm) electric washer/dryer

Advertisement

Electrical Connection Options
If your home has:
And you will be
Go to Section
connecting to:
4-wire receptacle
A UL listed,
4-wire connection:
(NEMA Type 14-30R)
120/240 volt
Power supply cord
minimum,
30 amp, dryer
power supply
cord*
4-wire direct
A fused
4-wire connection:
disconnect or
Direct Wire
circuit breaker
box*
1. Remove center terminal block screw.
2. Remove neutral grounding wire (green with yellow stripes)
from internal ground conductor screw. Fasten it under center,
silver-colored terminal block screw.
A
/,
,,r
3-wire receptacle
A UL listed,
(NEMA type 10-30R)
120/240 volt
_)
minimum,
30 amp, dryer
power supply
cord*
3-wire connection:
Power supply cord
3-wire direct
A fused
3-wire connection:
disconnect or
Direct Wire
circuit breaker
box*
*If local codes do not permit the connection of a frame-grounding
conductor to the neutral wire, go to "Optional 3-wire connection"
section.
4-wire connection:
Power supply cord
IMPORTANT: A 4-wire connection is required for all mobile
homes and where local codes do not permit the use of 3-wire
C
D
connections.
B
F
E
G
A. 4-wire receptacle
(NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. _" (1.9 cm) UL listed strain relief
G. Ring terminals
A. Center silver-colored
terminal block screw
B. Neutral grounding
wire (green with yellow stripes)
C. Internal ground conductor screw
3. Move the green painted screw from the internal to the external
ground conductor location. Connect ground wire (green or
bare) of power supply cord to external ground conductor
screw. Tighten screw.
4. Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block. Tighten screw.
B
/
o
...............
C
D
A. Neutral wire (white or center wire)
B. Center silver-colored
terminal block screw
C. Neutral grounding
wire (green with yellow stripes)
D. External ground conductor
screw
E. Green or bare wire of power supply cord
F Internal ground conductor
location
G. 3/4" (1.9 cm) UL listed, strain relief
5. Connect the other wires to outer terminal block screws.
Tighten screws.
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.