Split System Submittal Data
Ceiling Recessed Air Conditioner
System: KS18NB4U Indoor/Outdoor: CS-KS18NB4UW/CU-KS18NKU
Grille: CZ-18BT1U
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
Fuse Size, Max.
Compressor
DC Rotary Inverter
No. used
R.L. Amps - L.R.
(A)
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
(RPM)
No. Motors
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
(RPM, High))
No. Motors
(Hi/Med/Low)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Aluminum Plate Fin & Copper Tube
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.))
Tube Size
Drain Connection Size
General Data (at 230V)
230/208/1/60
(A)
(A)
9.8/10.6-20
Propeller
16-17/32-1
Direct-3
8-820/850
(W)
(HIGH))
(A)
Aluminum Fin and Copper Pipe
Corrugated Plate - Inner Rifl ed
2-18.1
(sq.ft.))
(in.)
Turbo
12-5/8/5-3/4-1
3+Auto
(W)
341/294/253
(A)
Slit Plate & Inner Rifl ed
2-18.1
(in.)
(in.)
23/32"
Approval:
Date:
Construction:
Unit #:
Drawing #:
20
20
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max (ft.)
Lift Diff erence, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
40-1
524
Outdoor Unit
0.5
Weight
Net
Shipping
6.4
9/32"
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
8-720
Sensible Capacity
30-1
Latent Capacity
SEER
Dehumidifi cation
44
.3
Amps
Power Inputs
Outdoor Sound Rating
2.94
9/32"
Electric Expansion Valve
(in O.D. Dishcharge)
(in O.D. Suction)
(in.)
(uncrated)
11-1/16 x 22-5/8 x 22-5/8
(crated)
11-13/32 x 24-3/16 x 28-1/8
(uncrated) 26-3/8 x 34-21/32 x 11-7/32
(crated) 29-1/8 x 39-27/32 x 14-31/32
Indoor
(lbs.) 35.3
(lbs.) 41.9
(cu.ft.) 4.59
(BTU/H)
17,500 (4,000-17,500)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
1860(250-1860)
(dB-A)
R410A
2.87
Flare
100
50
1/4"
1/2"
H x W x D
Outdoor
97.0
105.8
9.88
10,600
6,900
16
4.89
8.3(1.2-8.3)
51

Advertisement

loading

Summary of Contents for Panasonic KS18NB4U

  • Page 1 Split System Submittal Data Ceiling Recessed Air Conditioner System: KS18NB4U Indoor/Outdoor: CS-KS18NB4UW/CU-KS18NKU Grille: CZ-18BT1U Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: General Data (at 230V) Power V/PH/Hz 230/208/1/60 Circuit Ampacity Fuse Size, Max.
  • Page 2 Dimensions Features Options Available Controls Refrigerant Line Set Microprocessor Remote Controller Fresh Air Intake Knock-out LCD Wireless Type, Temp. Sensor Built In Temperature Control Airduct Extension IC Thermostat Timer Condensate Drain Pump Standard 24 Hr Program; 1HR ON/OFF Night Setback Hard Wired Remote Controller Available Built-In...