5.3

Address DIP Switches

The address DIP switches are used to assign an
address to the DX4010V2.
Refer to Table 3 on page 8 for DIP switch option bus
address settings.
Refer to Table 4 on page 9 for DIP switch SDI bus
address settings.
Refer to Figure 7 for proper DIP switch orientation.

Figure 7: DIP Switch Location and Orientation

1
P3
ON
1
2
3
4
5
1
2
4
8
16
2
1- Address DIP switches
2- Address example (option bus Address 0)
3- OFF position
4- ON position
Bosch Security Systems, Inc. | 9/08 | F01U083036-01
DX4010V2 | Installation Instructions | 6.0
LED
Rx Tx
Tx
Rx
BUS
SER
P2
DB9 GND
ENABLE
3
6
7
8
32
64 128

Remote Programming Direct Connection

6.0 Remote Programming
Direct Connection
The DX4010V2 can be used to create a local direct
connection for remote programming of a compatible
control panel.
Option Bus: Set the address DIP switches to
Address 0. Refer to Table 3 on page 8.
SDI Bus: Set the address DIP switches to Address
88. Refer to Table 4 on page 9.
Consult your control panel's installation guide for
specific wiring connections.
A DB9 to DB9 null-modem cable is
required when using the direct
connection method.