Hitachi L700 SERIES Quick Reference Manual page 55

Hide thumbs Also See for L700 SERIES:
Table of Contents

Advertisement

Code
Function name
C111
Overload setting (2)
C121
[O] input zero calibration
C122
[OI] input zero calibration
C123
[O2] input zero calibration
C130
Output 11 on-delay time
C131
Output 11 off-delay time
C132
Output 12 on-delay time
C133
Output 12 off-delay time
C134
Output 13 on-delay time
C135
Output 13 off-delay time
C136
Output 14 on-delay time
C137
Output 14 off-delay time
C138
Output 15 on-delay time
C139
Output 15 off-delay time
C140
Output RY on-delay time
C141
Output RY off-delay time
C142
Logical output signal 1 selection 1
C143
Logical output signal 1 selection 2
C144
Logical output signal 1 operator selection
C145
Logical output signal 2 selection 1
C146
Logical output signal 2 selection 2
C147
Logical output signal 2 operator selection
C148
Logical output signal 3 selection 1
C149
Logical output signal 3 selection 2
C150
Logical output signal 3 operator selection
C151
Logical output signal 4 selection 1
C152
Logical output signal 4 selection 2
C153
Logical output signal 4 operator selection
C154
Logical output signal 5 selection 1
C155
Logical output signal 5 selection 2
C156
Logical output signal 5 operator selection
C157
Logical output signal 6 selection 1
C158
Logical output signal 6 selection 2
C159
Logical output signal 6 operator selection
C160
Input terminal response time setting 1
C161
Input terminal response time setting 2
C162
Input terminal response time setting 3
C163
Input terminal response time setting 4
C164
Input terminal response time setting 5
C165
Input terminal response time setting 6
C166
Input terminal response time setting 7
C167
Input terminal response time setting 8
C168
Input terminal response time setting FW
Multistage speed/position determination
C169
time
(Note)<>indicate the setting range of 90 to 160kW
Monitored data or setting
0.0 to 1.50 x "rated current" (A)
<0.0 to 1.50 x "rated current" (A)>
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
10ms)
4 - 13
Chapter 4 List of Data Settings
Default
_FF
Rated
current of
inverter
Factory
setting
Factory
setting
Factory
setting
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
1
1
1
1
1
1
1
1
1
0
Setting
Change
during
during
operation
operation
(allowed
(allowed
or not)
or not)