Conettix D6600/D6100i | Installation and Operation Guide | 10.0 D6600/D6100i Operation

10.1.6 Buzzer Operation

In the Manual Mode, an Operator Alert Buzzer
sounds when a message is received until you press
the [ACKNOWLEDGE] key. The buzzer operation is
programmable and can be disabled when the receiver
is programmed for the Automatic Mode.
10.1.7 Reporting Devices: Primary and Secondary
A reporting device is any device that can print or
display messages from the D6600/D6100i. This
includes the central station automation computer or
an external printer. You can enable the external
printer and designate it as the primary or secondary
device. The automation computer is always a primary
device unless disabled. Primary reporting devices
receive all reports generated by the D6600/D6100i.
Secondary reporting devices receive input from the
D6600/D6100i only when all primary devices fail.
UL 1981 allows the receiver to suppress
printing during normal automation
system operation if the printer starts
printing upon automation system failure.
If the receiver is in the Automatic Mode and all of the
primary reporting devices (such as printers and
computers) fail, the receiver re-routes the messages
to the secondary reporting device(s). If you program
the receiver for no secondary reporting devices or if
all secondary reporting devices fail, the
D6600/D6100i automatically switches to Manual
Mode. When the receiver restores automation to
normal operation, the D6600/D6100i returns to the
Automatic Mode after the user manually
acknowledges the last buffered signal.
16
10.2

Normal Operation Mode

In Normal Operation Mode, the D6600/D6100i sends
messages immediately or in blocks to reporting
devices (such as printers and computers) as soon as
the devices are ready to receive the information.
Signals do not remain visible in the display. If all
reporting devices fail, the D6600/D6100i reverts to
Manual Mode until a device returns to service.
Normally, the D6600/D6100i sounds the Operator
Alert Buzzer for new events received when the
automation link fails.
Typical Alarm Receiving Sequence
1. An alarm occurs on Zone 3 at subscriber location
456. The user programs Account 456 to report to
Line 01 and does not assign Line 01 to report to a
call group.
2. The OL LED glows green when the receiver
answers the call and receives data.
3. The primary reporting device (such as an external
printer or automation computer) activates.
If the external printer is a primary reporting device
and Line 01 is not assigned to Group Reporting, it
prints:
If Line 01 is assigned to Group 1 Reporting, the
receiver's external printer prints:
4. Line 01 hangs up