Conversion Front Nat. Gas To Universal Lpg; To Change Injectors - Bosch PHW206FAU User Instruction & Installation Manual

For use with natural gas and universal lpg
Table of Contents

Advertisement

Coverting the cooktop
from Nat.Gas to
Universal LPG
11

To change injectors

All work involved in installation, setting and adaptation
to a different gas type must be carried out by authorised
personnel from our Service Centre and must comply
with current regulations and the conditions laid down by
the local gas company.
Request change-over injectors from our customer service
deparment (refer injector chart below for sizes).
Natural Gas
Burner
Hourly Gas
Consumption
(MJ)
4,0
Small
6,5
Medium
12,0
Large
13,0
wok (Center)
13,0
wok (Left front)
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
1 Remove the trivets, burner caps and burner heads.
7
Refer Fig. .
2 Change the injectors using a 7-mm socket wrench
and be sure to tighten them down properly so that
they are fully airtight. Refer Fig. .
3 Re-assemble the burner component parts in reverse
order.
NOTE: it is not necessary to adjust the primary air control
on these burners.
6
7
Universal LPG
Hourly Gas
Injector
Consumption
size
(MJ)
(mm)
3,25
0.90
6,25
1.18
10,0
1.60
13,25
1.65
10,8
1.65
8
8
Injector
size
(mm)
0.50
0.67
0.85
0.97
0.93
7 mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ppq726b90aPhl206fauPph626b90a

Table of Contents