Installation instructions
Minimum
Clearance
Other Than Alcove or Closet Installation
Minimum
clearance
m combustible
surfhces
and for air opening
are: 0 in. clearance
bofl_ sides and
1 in. rear. Consideration
must
be
given m provide adequate
clearance
for proper
operation
and service.
FT]PREPARING FOR iNSTALLATiON
OF NEW DRYER
TIP: Install your dryer before
installing
your washer,
This will allow better access when installing
dryer exhaust,
DiSCONNECTiNG
GAS
TURN GAS
SHUT-OFF VALVE
Id_
TOTHE OFF
LL_._:q:
v
DISCONNECTANDDISCARDOLD
_/__
FLEXIBLE GAS CONNECTOR
AND
OLD TRANSITION DUCTING
MATERIAL. REPLACE WITHNEW
CSA(AGA) APPROVED
FLEXIBLE
GAS LINE CONNECTOR
ANDUL
APPROVED
TRANSITION DUCT.
a'k
_WARNING
- NEVER
REUSE
OLD
FLEXIBLE
CONNECTORS.
The
use of okt flexible
connectors
can cause
leaks and
personal
ii_i ury. Always use new flexible
connectors
when
installing
gas appliances.
REMOVING
LiNT FROM
WALL
EXHAUST
OPENING
* Remove
and discard
existing
plastic
or metal
foil
transition
duct and
replace
with UL listed
transition
duct.
WALL
/
INTERNAL DUCT
CHECK T HAT EXHAUST
OPENING
HOOD DAMPER O PENS
ANDCLOSES F REELY.
TILT THEDRYER S IDEWAYS
ANDREMOVE T HEFOAM
SHIPPING P ADS BY
PULLING A TTHE SIDES
ANDBREAKING THEM
AWAY FROM THE DRYER
LEGS. BESURE TO
REMOVE ALLOFTHE
FOAM PIECES AROUND
THE LEGS.
_q GAS REQUIREMENTS
WARNING
* Installation
IIIUSE
conf()l'IIl
tO
local codes
and ordinances,
or in their
absence,
the NATIONAL
FUEL
(;AS CODE,
ANSI Z223.
* This gas dryer is equipped
with a Valve & Burner
Assem-
bly for use only with natural
gas. Using
conversion
kit
WE2 5X0217,
your local smwice organization
can convert
this dwer
for use with propane
(LP) gas. ALL CONWER-
SIONS
MUST
BE MADE
BY PROPERLY
TRAINED
AND
QUALIFIED
PERSONNEL
AND
IN ACCOR-
DANCE
WITH
LOCAL
CODES
AND ORDINANCE
REQUIREMENTS.
* The dxyer must
be disconnected
flom
the gas supply
piping
system
during
any pressure
testing
of that system
at a test pressure
in excess
of 0.5 PSI (3.4 KPa).
* The dryer
must be isolated
flom
the gas supply
piping
system
by closing
the equipment
shut-offvalve
during
any pressure
testing
of the gas supply
piping
of test
pressme
equal
to or less than
0.5 PSI (3.4 KPa).
DRYER GAS SUPPLY CONNECTION
l
2-5/8"
" 3/8"NPT MALE THREAD G AS SUPPLY
NOTE: Addto vertical d imension
thedistance between cabinet
bottomto floor.
GAS SUPPLY
* A 1/8-in.
National
Pipe Taper
thread
plugged
rapping,
accessible
for test gauge
connection,
must be installed
immediately
upstream
of the gas supply
connection
to
the dryer. Contact
your local
gas utility should
you have
questions
on the installation
of the plugged
tapping.
* Supply
line is to be 1/2-in.
rigid pipe and
equipped
with
an accessible
shut-off
within
6 fL oL and in the same
room with the dwer.
* Use pipe thread
sealer
compoundor
Teflon
rope
appropriate
for naturabr
LP gas.
* You must use with this dryer a flexible
metal connector
listed connector
ANSI Z21.24 / CSA 6.10. The length
of
the connect
shall not exceed
3 fL
* Connect
flexible
metal
connector
to dryer and
gas supply.
* Open
shut-off
valve.
2