Download Print this page

Installation - GE DMCD330GH1WC Installation Instructions Manual

Advertisement

Installation
[]
RECONNECTING
GAS
Listed connector
ANSI Z21.24
/ CSA 6.10
118" NPT PIPE
NEWMETAL
PLUG FOR
GAS
FLEXIBLE GAS
INLET PRESSURE
LINECONNECTOR
ADAPTER
ELBOW
3/8" NPT
SHUT-OFF
PIPE SIZE
ITEMSNOT SUPPLIED
AT LEAST 1/2"
Note: The connector and fittings are designed for use onty
on the original insta[tation
and are not to be reused for
another appliance or at another location. Keep flare end of
adaptor free of ]rease, oi[ and thread sealant.
Caution: Use adapters as shown. Connector nuts must not
be connected directly
to pipe threads.
APPLYPIPECOMPOUND
TO THEADAPTERAND
DRYER GAS INLET.
TIGHTEN THE FLEXIBLE
GAS LINE USING TWO
ADJUSTABLE WRENCHES.
Instructions
APPLYPiPECOMPOUND
TOALL MALETHREADS.
TIGHTEN ALL CONNECTIONS
USING TWO ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
3
LEAK TEST
[,_
WARNING
- NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS.
OPEN
GASVALVE.
Check alt connections
for leaks with soapg solution or equivalent.
Apply soap solution.
Leak test solution
must not contain
ammo-
nia which could cause damage
to the brass fittings.
If leaks are
found, close valve, retighten the joint, and repeat the soap test.