The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence
and 2U density for a variety of rack deployments and applications.
Front View:
1.
Access panel
2.
Front LED Indicators
3.
Power on/off
4.
Optional DVD-RW or DVD-ROM drive
5.
Front USB Ports (2)
6.
Non-Hot Plug Non Redundant fans (4 fans)
7.
Air Baffle
8.
PCI Cage
9.
System Board
What's New
Support for HP 3TB 3G SATA 7.2K 3.5in MidlLine Hard Drive
DA - 13248 Worldwide — Version 53 — September 24, 2012
HP ProLiant DL180 Generation 6 (G6)
Rear View:
1.
Redundant Power Supply Bay (Optional)
2.
Power Supply Cable Socket
3.
Low Profile Card Slot
4.
PCI Expansion Card Slot
5.
PCI Expansion Card Slot
6.
UID LED Button
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
Page 1

Advertisement

loading

Summary of Contents for HP DL180

  • Page 1 HP ProLiant DL180 Generation 6 (G6) Overview The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence and 2U density for a variety of rack deployments and applications.
  • Page 2: Standard Features

    QuickSpecs HP ProLiant DL180 Generation 6 (G6) Standard Features NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - Factory Integrated Models" section. Processor Intel® Xeon® X5660 (2.80GHz/6-core/12MB/95W, DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor NOTE: Available through Configure To Order only.
  • Page 3 NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator. Network Controller HP NC362i Integrated Dual Port Gigabit Server Adapter Expansion Slots Slot Number Bus Speed...
  • Page 4 NOTE: All Hard drive bay options except 4LFF require HP Smart Array P410 or P212 controller. NOTE: Full Height/ Full Length Riser Option is not available when the Rear 2LFF drive bays is selected for the system.
  • Page 5 25.0TB (25 x 1.0TB) Hot Plug 2.5" SAS SSD 20.0TB (25 x 800GB) Interfaces Network RJ-45 (Ethernet) 2 10/100/1000 NIC ports (plus 1 dedicated for the HP ProLiant Lights Out 100i Remote Management) Serial Graphics 5 total ports: (2) front, (2) rear, (1) optional internal NOTE: In order to connect a USB device internally, the internal USB Cable G6 Kit must be used (P/N 536769-B21).
  • Page 6 Standard Features Common Slot Power HP has a new design for ProLiant power. The new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares Supply and allows HP to offer multiple power solutions to fit the customers' needs.
  • Page 7 HP ProLiant DL180 Generation 6 (G6) Standard Features Form Factor Rack (2U), (3.5 in/8.89 cm) Embedded Manageability HP Lights-Out 100 HP LO100 with Optional LO100 Advanced Licenses for Virtual KVM and Virtual Media. (LO100) Advanced Features: Embedded IPMI standard reporting...
  • Page 8 Easy Set-up CD Easy Set-up CDs are available on all 100-series G6 servers and are also available as an ISO image web download. HP ProLiant Easy Set-up CDs provide easy, step-by-step, single and multi-server server utilities for the ProLiant 100-series G6 servers to streamline server setup for 100-series G6 servers.
  • Page 9 Secure Shell (SSH) Warranty This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners. Hardware diagnostic support and parts replacement is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase.
  • Page 10: Optional Features

    Linux-based management consoles. See www.hp.com/go/ic-linux HP Insight Control include one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight...
  • Page 11 HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.
  • Page 12: Service And Support

    Capitalizing on HP ProLiant server and HP BladeSystem capabilities requires a service partner who understands your increasingly complex business technology environment. That's why it makes sense to team up with the people who know HP infrastructure hardware and software best - the experienced professionals at HP Services.
  • Page 13 3-Year HP 24x7 4 hour Response, Hardware Support Onsite Service Provides you with rapid remote support and if required an HP authorized representative who will arrive on site any time and day of the year to begin hardware maintenance service within 4 hours of the service request being logged.
  • Page 14 Internal mini-SAS cable (P/N 496013-B21). NOTE: Upgrading to 8 Hot Plug SATA/SAS hard drives requires the addition of a HP 2U G6 8HDD LFF DL18X KIT (P/N 506924-B21), storage controller (Smart Array P410/256MB recommended), and two Internal SATA/SAS cables (mini-SAS cable (P/N 496013-B21).
  • Page 15 8GB (2 x 4GB) PC3-10600R-9 (RDIMM) 590638-xx1 NOTE: Total 12 DIMM slots Network Controller HP NC362i Integrated Dual Port Gigabit Server Adapter Storage Controller HP Smart Array P410/256MB BBWC Controller (RAID 0/1/1+0/5/5+0) NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-B21) is...
  • Page 16 Network Controller HP NC362i Integrated Dual Port Gigabit Server Adapter Storage Controller HP Smart Array P212 /256MB BBWC Controller (RAID 0/1/1+0/5/5+0) NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-B21) is required to enable RAID 6, 6+0 Hard Drive...
  • Page 17 16GB (4 x 4GB) PC3-10600R-9 (RDIMM) 590640-xx1 NOTE: Total 12 DIMM slots Network Controller HP NC362i Integrated Dual Port Gigabit Server Adapter Storage Controller HP Smart Array P410/256MB BBWC Controller (RAID 0/1/1+0/5/5+0) NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-B21) is...
  • Page 18 NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements.
  • Page 19 HP DL180 G6 Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W) FIO Processor Kit 590605-L21 HP Memory Registered RDIMMs HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500656-B21 HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500658-B21...
  • Page 20 HP 2U G6 25 SFF CAGE FIO Kit 516011-B21 NOTE: Selection of the 12 LFF or 25 SFF drive cage requires an HP Smart Array P212, P410 (any except Zero Memory) or P812 controller. HP DL180 G6 Rear 2 Large Form Factor Drive Kit...
  • Page 21 HP ProLiant DL180 Generation 6 (G6) Core Options NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information.
  • Page 22 Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. HP Memory Registered RDIMMs HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500656-B21 HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500658-B21 HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit...
  • Page 23 HP 450GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive 581284-B21 HP 300GB 6G SAS 15K rpm SFF (2.5-inch) Hot Plug Enterprise 3 yr Warranty Hard Drive 627117-B21 HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive 507127-B21 DA - 13248 Worldwide —...
  • Page 24 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Core Options HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive 512547-B21 SAS Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives NOTE: 3G Hard Drives will operate at up to 3.0 Gb/s in 4 drive models that use the embedded controller.
  • Page 25 HP ProLiant DL180 Generation 6 (G6) Core Options SATA Hot Plug LFF (3.5-inch) Entry (ETY) Drives HP 250GB 3G SATA 7.2K rpm LFF (3.5-inch) Entry 1yr Warranty Hard Drive 571230-B21 NOTE: Please see the QuickSpecs for Technical Specifications and additional specifications: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html...
  • Page 26 HP InfiniBand QLogic InfiniBand 4X QDR PCI-E G2 Dual Port HCA 583211-B21 HP InfiniBand 4X QDR ConnectX-2 PCIe G2 Dual Port HCA 592520-B21 HP InfiniBand 4X DDR ConnectX-2 PCIe G2 Dual Port HCA 592521-B21 NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13078_div/13078_div.html...
  • Page 27: Additional Options

    HP ProLiant DL180 Generation 6 (G6) Additional Options NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information.
  • Page 28 The license entitlement certificate must be redeemed online in order to obtain a license key. HP Insight Cluster Management Utility Flexible License with 3 years of 24x7 updates BD476A and technical support NOTE: These part numbers can be used to purchase one certificate for multiple licenses and support with a single activation key.
  • Page 29 Additional Options HP I/O Accelerator Second Generation Accelerators Options HP 365GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers 673642-B21 HP 785GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers 673644-B21 HP 1205GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers...
  • Page 30 NOTE: Cable for use connecting the Smart Array P800 Controller to internal hard disk drives on select HP ProLiant G6 Servers. HP Smart Array Hot Plug Advance Pack for B110i w/1y 24x7 Supp Physical 1 Svr LTU TC421A HP Smart Array Advanced Pack including 1yr 24x7 Technical Support and Updates...
  • Page 31 TC331AAE HP Data Protector Express V5.0 for 10 Servers E-LTU TC332AAE HP Basic Upgrade to Data Protector Express V5 for 1 Server E-LTU TC333AAE NOTE: Only one of these Data Protector Express base products is required. To see available options: http://www.hp.com/go/dataprotectorexpress...
  • Page 32 HP P212 SAS Smart Array Controller (462828-B21) is recommended. HP 1/8 G2 Ultrium 920 SAS Autoloader AH558A NOTE: Requires HP 1U Tape Autoloader Rack-Mount Kit (AH166A) for rack installation. Connection using the HP P212 SAS Smart Array Controller (462828-B21) is recommended.
  • Page 33 NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html. Brocade Fibre Channel HBAs HP 81B 8Gb 1-port PCIe Fibre Channel Host Bus Adapter AP769B HP 82B 8Gb 2-port PCIe Fibre Channel Host Bus Adapter AP770B...
  • Page 34 NOTE: For additional information on sizing your server, please reference: http://www.upssizer.com NOTE: Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units.
  • Page 35 NOTE: For additional information on HP Power Distribution Units including accessories please go to: www.hp.com/go/pdu. NOTE: Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units.
  • Page 36 HP 17.3kVA 24A 415V Three Phase IEC309 NA Core Intelligent Power Distribution Unit AF901A HP 22kVA 32A 400V Three Phase 12 Outlet Core INTL Intelligent Power Distribution Unit AF538A HP 17.3kVA 24A 415V Three Phase 12 Outlet Core NA/JP Intelligent Power Distribution...
  • Page 37 Hardware Services Next Business Day On-Site Service HP 3 year Next business day ProLiant DL18x Hardware Support UH270E Hardware Services 6-Hour Call to Repair On-Site Service HP 3 year 6 hour 24x7 Call to Repair ProLiant DL18x Hardware Support UH273E HP Installation ProLiant DL18x Service UH301E NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack.
  • Page 38 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Memory NOTE: Memory configurations listed do not apply to "Factory Integrated Models". HP ProLiant DL180 G6 Standard Memory (depending on model) 4GB (1 x 4GB) PC3-10600R-9 Registered memory, with Advanced ECC Capabilities Memory installed.
  • Page 39 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Memory Unbuffered with ECC DIMMs Registered DIMMS (RDIMMs) (UDIMMs) DIMM Type -> Single Single Rank Rank (1R) Dual Rank (2R) Quad Rank (4R) (1R) Dual Rank (2R) DIMM Rank -> DIMM Capacity ->...
  • Page 40 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Memory 12 DIMM SLOTS (6 per CPU node) CPU1 CPU2 slot # population order slot # population order Chnl 1 Chnl 1 Chnl 2 Chnl 2 Chnl 3 Chnl 3 Standard memory configuration (1 CPU model)
  • Page 41 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Memory Standard memory replaced with optional memory (1 CPU model) RDIMM maximum configuration 96GB, consisting of six (6) 16GB quad-rank PC3-8500 RDIMMs CPU1 CPU2 slot # population order slot # population order Chnl 1...
  • Page 42 DDR3 memory options part number decoder HP Memory Registered RDIMMs HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500656-B21 HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500658-B21 HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit...
  • Page 43 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Memory HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power 604504-B21 Memory Kit HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power 604506-B21 Memory Kit HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit...
  • Page 44: Drive Support

    QuickSpecs HP ProLiant DL180 Generation 6 (G6) Storage 8 Drive Cage with DVD-Drive bay Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays DVD-ROM, DVD RW 12 Drive Cage 1-12 Twelve 3.5" Hot Plug SAS/SATA Hard Drive Bays 13-14 Two Rear 3.5" Hot Plus SAS/SATA Hard Drive Bays...
  • Page 45 HP Smart Array P410/512 MB FBWC Controller HP Smart Array P410/1G FBWC Controller HP Smart Array P812/1G FBWC Controller HP Smart Array P800/512 BBWC Controller HP Smart Array Hot Plug Advance Pack for B110i SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives Quantity Position...
  • Page 46 100GB 3G SATA MLC LFF HP Smart Array P812/1G FBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array B110i Hot Plug Advance Pack for B110i SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives Quantity Position...
  • Page 47 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Storage HP Smart Array P410/512 MB BBWC Controller HP Smart Array P410/512 MB FBWC Controller HP Smart Array P410/1G FBWC Controller HP Smart Array P812/1G FBWC Controller HP Smart Array P800/512 BBWC Controller...
  • Page 48 NOTE: For the complete range of tape drives, autoloaders, libraries and media, including the internal fitting models, see: http://www.hp.com/go/tape. For the complete range of D2D Backup Systems see: http://www.hp.com/go/d2d. For the complete range of RDX drives and media see: http://www.hp.com/go/rdx. For hardware and software compatibility of HP disk and tape backup products see: http://www.hp.com/storage/SPOCK...
  • Page 49 LTO-5 Ultrium 3000 LTO-5 Ultrium 3280 1U Rack-Mount Kit 3U Rack-Mount Kit HP SCSI Tape Autoloaders External HP SC11Xe Ultra320 Single Channel/ PCIe x4 SCSI Host Bus Adapter 412911-B21 DAT 72x10 Autoloader 1/8 G2 Autoloader HP SCSI Tape Libraries External...
  • Page 50 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Storage HP D2D Backup Systems, External Embedded Network Controller. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus Adapter is iSCSI recommended. D2D2500i D2D4000i HP D2D Backup Systems, External Direct server attach is not supported, requires connection via SAN fabric.
  • Page 51: Power Specifications

    QuickSpecs HP ProLiant DL180 Generation 6 (G6) Power Specifications HP 460W Common Slot Gold Hot Plug Power Supply Kit Part Number 503296-B21 Input Voltage Range (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) Maximum Rated Output Wattage...
  • Page 52 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Power Specifications HP 460W Common Slot Platinum Hot Plug Power Supply Kit Part Number 593188-B21 Input Voltage Range (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) Maximum Rated Output Wattage...
  • Page 53 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Power Specifications HP 1200W Common Slot -48VDC Hot Plug Power Supply Kit Part Number 437573-B21 Input Voltage Range (Vrms) 36-72 Frequency Range (Nominal) (Hz) Nominal Input Voltage (Vrms) Maximum Rated Output Wattage 1200...
  • Page 54: Technical Specifications

    To review typical system power ratings use the Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy- efficient Click on the system of interest. Example: DL180 G6 Follow the instructions of the next screens. Power Supply Output Rated Steady-State...
  • Page 55 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Technical Specifications System performance may be reduced if operating with a fan fault or above 30°C (86°F). Non-operating -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). Relative Humidity Operating 10 to 90% relative humidity (Rh), 28°C (82.4°F)
  • Page 56 QuickSpecs HP ProLiant DL180 Generation 6 (G6) Technical Specifications Smart Array P212 Disk Drive and Enclosure 3G SAS (Serial Attached SCSI) Controller Interface 1.5G SATA (Serial ATA) SAS Connectors 1 internal/1 external (Mini-SAS) x8 wide port connectors Cache Memory Speed DDR-2/533 MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum...
  • Page 57 Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.