GE ZDBI240WCII Installation Instructions Manual page 3

Wine chiller, wine reserve and beverage center
Table of Contents

Advertisement

Desi n Guide
THE INSTALLATION
SPACE
34-I/2"-35"
/
"23-3/4" Min. Standard
*'24-1/4" Min. StainlessSteelFlush
**'24-3/4" Min. FramedFlush
NOTE:
Handle and handle
standoff depth is 1-3/4"
*For a standard installation of Custom-Framed unit: The
product must be installed so that the front face will project 2"
forward of adjacent cabinets. This position will allow a full door
swing and prevent interference with adjacent cabinetry. The
opening between cabinets must be 23-3/4" minimum.
*For a standard installation of Stainless Steel unit: The product
must be installed so that the front face will project 1-3/4"
forward of adjacent cabinets. This position will allow a full door
swing and prevent interference with adjacent cabinetrg. The
opening between cabinets must be 23-3/4" minimum.
**For a flush installation of Stainless Steel unit: Install a
1/2"-wide filler strip on the hinge side.The filler strip will act as
a spacer between the door case and adjacent cabinets and will
prevent interference with the cabinet door swing. Recessthe
filler strip 2" back from the front face of the unit, or even with
the front edge of the product case (behind the gasket).The width
of the opening must be 24-1/4" (includingthe 1/2" filler strip).
***For a flush installation of Custom-Framed unit: Install a
1"-wide filler strip on the hinge side. The filler strip will act as
a spacer between the door case and adjacent cabinets and
will prevent interference with the cabinet door swing. Recess
the filler strip 2" back from the front face of the unit, or even with
the front edge of the product case (behind the gasket).The width
of the opening must be 24-3/4" (includingthe 1" filler strip).
• The wine chiller, wine reserve and beverage center can
be installed freestanding.
Additional Specifications
• A 120 volt 60Hz.,15 or 20 amp power supplg is required.
An individual properlg grounded branch circuit or circuit
breaker is recommended. Install a properlg grounded
3-prong electrical receptacle recessed into the back wall
as shown. Electricalmust be located on rear wall as shown.
NOTE:GFI(ground fault interrupter)is not recommended.
THE INSTALLATION
SPACE (cont.)
_
CABINET
.................................
.......................
Installation
Dim. A
/
]
Filler panel or cleat
to be set back even
with front of case.
Front edge of product case
I
Front face
*
These products will fit flush to
\
adjacent cabinets when installed
with a Dim. A-width filler panel
or cleat. The filler panel should
be recessed or set back behind
the door and even with the front
edge of the product case.
CABINET
Product
Dim:A
ZDWI240, ZDBI240
1"
ZDWC240,
ZDWR240
1/2"
ZDBC240, ZDBR240
1/2"
CABINET
Y
Dim.A
A
Standard
Installation
Frontedgeof productcase
Front face
In a standard installation,
'\_ °°
the product will project forward
of adjacent cabinets. See Dim. A.
PrOduct
Dim:A
ZDWI240, ZDBI240
2"
ZDWC240,
ZDWR240
1-3/4"
ZDBC240, ZDBR240
1-3/4"
CABINET

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zdbr240pcbsZdbc240ncbsZdwi240Zdbi240Zdwc240Zdwr240 ... Show all

Table of Contents