Clearance Requirements; Explosion Hazard - Frigidaire FFLG2022MW0 Installation Manual

Laundry center
Hide thumbs Also See for FFLG2022MW0:
Table of Contents

Advertisement

Available languages

Available languages

Manufactured
or mobile
home installation
1
Installation MUST conform to current Manufactured
Home Construction & Safety Standard, Title 24
CFR, Part 32-80 (formerly the Federal Standard
for Mobile Home Construction and Safety, Title 24,
HUD Part 280) or Standard CAN/CSAZ240 MH.
2
Dryer MUST be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting
that will not support combustion. Metal ducting
must be 4 inches (10.16 cm) in diameter with no
obstructions. Rigid metal duct is preferred.
3
If dryer is exhausted through the floor and area
beneath the mobile home is enclosed, the exhaust
system MUST terminate outside the enclosure with
the termination
securely fastened to the mobile
home structure.
4
Refer to previous sections in this guide for other
important exhaust venting system requirements.
5
When installing a gas dryer into a mobile home, a
provision must be made for outside make up air.
This provision is to be not less than twice the area
of the dryer exhaust outlet.
6
Installer MUST anchor this laundry center to the
floor with approved Mobile Home Installation Kit -
P/N 137067200.
Clearance requirements
EXPLOSION
HAZARD
Do not install the dryer where gasoline or other
flammables are kept or stored. If the dryer is installed
in a garage, it must be a minimum of 18 inches (45.7
cm) above the floor. Failure to do so can result in
DO NOT install your dryer in a closet with a solid door.
4
Closet door ventilation required: A minimum
of 120 square inches (774.2 cm 2) of opening,
equally divided at the top and bottom of the
door, is required. Openings should be located 3
inches (7.6 cm) from bottom and top of door.
Openings are required to be unobstructed when a
door is installed. A Iouvered door with equivalent
air openings for the full length of the door is
acceptable.
DO NOT INSTALL YOUR LAUNDRY CENTER:
1
In an area exposed to dripping water or outside
weather conditions. The ambient temperature
should never be below 60 ° F (15.6 ° C) to
maximize detergent effectiveness.
2
In an area where it will come in contact with
curtains, drapes, or anything that will obstruct
the flow of combustion and ventilation air.
3
On carpet. Floor MUST be solid with a maximum
slope of 1 inch (2.5 cm). To minimize vibration
or movement, reinforcement of the floor may be
Installation
in a Recess
or Closet
1 A dryer installed in a bedroom, bathroom, recess or
closet, MUST be exhausted outdoors.
2
No other fue! burning appliance shall be installed in
the same closet as the gas dryer.
3
Your dryer needs the space around it for proper
ventilation.
(7.63cm)
closet door
60 sq. in.
(387.1 cm 2)
f
60 sq. in.
(387.1 cm 2)