Fujitsu PRIMERGY SX650 Hardware Manual
Fujitsu PRIMERGY SX650 Hardware Manual

Fujitsu PRIMERGY SX650 Hardware Manual

Storage blade

Advertisement

Quick Links

Areas Covered
Before Reading This Manual
This section explains the notes for your safety and conventions used in this manual. Make sure
to read before using this product.
Chapter 1 Names and Functions
This chapter explains the names and functions of the parts.
Chapter 2 Installation and Connection
This chapter explains how to install this product in the chassis, and how to connect it to the
Server Blade.
Chapter 3 Operation
This chapter explains operating this product.
Chapter 4 Operation and Maintenance
This chapter explains maintenance after starting to use the server.
Appendix
This chapter explains the specifications of this product.
PRIMERGY SX650 Storage Blade Hardware Guide
4
1

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu PRIMERGY SX650

  • Page 1 PRIMERGY SX650 Storage Blade Hardware Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read before using this product. Chapter 1 Names and Functions This chapter explains the names and functions of the parts.
  • Page 2: For Your Safety

    Note that data protection is not guaranteed when repairs are performed. It is the customer's responsibility to maintain backup copies in advance. In case of data loss, Fujitsu assumes no liability for data maintenance or restoration and damages that occur as a result of the data loss for any reason, except for items covered under warranty.
  • Page 3 PRIMERGY SX650 Storage Blade Hardware Guide Introduction This manual explains the basic usage of the PRIMERGY SX650 Storage Blade (PG-B6ADC1) that will be installed in the PRIMERGY BX600 S3 Blade Server System Unit, and connected to the PRIMERGY BX620 S4 Server Blade. Before using this product, read this manual and related manuals to ensure correct use of this product.
  • Page 4 ■ Abbreviations The following expressions and abbreviations are used throughout this manual. Product name Expressions and abbreviations PRIMERGY SX650 Storage Blade Storage Blade or this product PRIMERGY BX620 S4 Server Blade Server Blade PRIMERGY BX600 S3 Blade Server System Unit...
  • Page 5 PRIMERGY SX650 Storage Blade Hardware Guide Safety For safe use of this product, it is vital that the following warnings are heeded. ■ Product failure • In the event of heat, smoke, or a strange smell being emitted from this product, immediately turn the Server Blade off and unplug the chassis power cable from the power source, and contact an office listed in the "Contact Information"...
  • Page 6 All product names used are trademarks or registered trademarks of their respective manufacturers. All products are copyrights of their respective manufacturers. Copyright FUJITSU LIMITED 2008...
  • Page 7: Table Of Contents

    PRIMERGY SX650 Storage Blade Hardware Guide Contents Chapter 1 Names and Functions 1.1 Front ..........10 Chapter 2 Installation and Connection 2.1 Installation and connection .
  • Page 9: Names And Functions

    Chapter 1 Names and Functions This chapter explains the names and functions of the parts. 1.1 Front ........
  • Page 10: Front

    Chapter 1 Names and Functions 1.1 Front This section explains the names and functions of the parts. a Release latch This latch is used when installing or removing this product. b Hard disk access LED This LED lights up green when data is being written to or read from the internal hard disk unit. c Hard disk status LED This LED lights up or blinks as follows depending on the internal hard disk unit status.
  • Page 11: Power Led

    PRIMERGY SX650 Storage Blade Hardware Guide e Power LED Indicates this product's power status. LED status Description Powered off Green Powered on f SAS connector Connects the SAS cable (one cable is provided standardly).
  • Page 12 Chapter 1 Names and Functions...
  • Page 13: Chapter 2 Installation And Connection

    Chapter 2 Installation and Connection This chapter explains how to install this product in the chassis, and how to connect it to the Server Blade. 2.1 Installation and connection ..... . .
  • Page 14: Installation And Connection

    BIOS may be required to be updated. For information about combination of firmware and BIOS, refer to the following website to download and update an appropriate firmware or BIOS. If an appropriate firmware or BIOS is not applied, this product may not operate properly. http://primergy.fujitsu.com...
  • Page 15: Connecting The Sas Cable

    PRIMERGY SX650 Storage Blade Hardware Guide 2.1.2 Connecting the SAS cable To operate this product, connect to the SAS RAID Ctrl in the Server Blade using the SAS cable. ■ Connecting the SAS cable Turn off the Server Blade to be connected before connecting the SAS cable.
  • Page 16 Chapter 2 Installation and Connection Insert the SAS cable into the respective SAS connectors on this product and the Server Blade (SAS RAID Ctrl) at the same time. Insert it until it clicks (locked). SAS cable The SAS cable is universal. ■...
  • Page 17: Chapter 3 Operation

    Chapter 3 Operation This chapter explains operating this product. 3.1 Turning this product on/off ......3.2 Installing the internal hard disk unit ....
  • Page 18: Turning This Product On/Off

    Chapter 3 Operation 3.1 Turning this product on/off This section explains how to turn this product on/off. 3.1.1 Turning on Press the Server Blade power switch to turn this product on. For the procedure for turning the Server Blade on, refer to "3.2 Turning On the Server" in "PRIMERGY BX600 S3 Blade Server System Unit Hardware Guide".
  • Page 19: Installing The Internal Hard Disk Unit

    PRIMERGY SX650 Storage Blade Hardware Guide 3.2 Installing the internal hard disk unit Up to five internal hard disk units can be installed in this product. This section explains how to install/remove an internal hard disk unit. When an array system is configured, replacing a faulty internal hard disk unit and adding an internal hard disk unit (hot-plug) can be performed during operation.
  • Page 20: Installation Location

    Chapter 3 Operation 3.2.1 Installation location Install internal hard disk units in the disk bays located on the front of this product. Make sure to install a dummy unit to restrict cold airflow in disk bays where internal hard disk units are not installed.
  • Page 21: Installation Procedure

    PRIMERGY SX650 Storage Blade Hardware Guide 3.2.3 Installation procedure The installation procedure for internal hard disk units is as follows. Touch a metal part of the chassis to discharge static electricity. Remove the dummy unit. Dummy units are installed in the bays where internal hard disk units are not installed.
  • Page 22: Removal Procedure

    Chapter 3 Operation 3.2.4 Removal procedure The removal procedure for internal hard disk units is as follows. Touch a metal part of the chassis to discharge static electricity. Remove the internal hard disk unit. 1. Open the cover while pressing the tab. 2.
  • Page 23: Operation And Maintenance

    Chapter 4 Operation and Maintenance This chapter explains maintenance after starting to use the server. 4.1 Troubleshooting ....... 4.2 Maintenance service .
  • Page 24: Troubleshooting

    Chapter 4 Operation and Maintenance 4.1 Troubleshooting If you think there may be a failure when operating, confirm the status of this product by referring to "4.1.1 Points to be checked" ( p.24), and contact your maintenance engineer. ■ • " This product has an error."...
  • Page 25 PRIMERGY SX650 Storage Blade Hardware Guide ■ This product is not turned on. Check the following. If you cannot solve the problem, leave this product as is and contact your maintenance engineer. • Is this product securely installed in the chassis server blade slot? •...
  • Page 26: Maintenance Service

    Chapter 4 Operation and Maintenance 4.2 Maintenance service For contact information about maintenance service details, products and services, refer to "Start Guide". 4.2.1 Contacting Maintenance Support Before contacting maintenance support, check the following. ■ Points to be checked • Product name and product ID Product ID MODEL.
  • Page 27 Appendix This chapter explains the specifications of this product. A Specifications ....... . .
  • Page 28: A Specifications

    Appendix Specifications This product's specifications are as follows. Item Functions and specifications Product name PRIMERGY SX650 Storage Blade Product ID PG-B6ADC1 Disk bay Installable number 5 (2.5 inch) Supported HDD capacity 2.5 inch SAS HDD (Rpm) 73.4GB (10,000rpm), 146.8GB (10,000rpm), 73.4GB (15,000rpm)
  • Page 29: Hardware Guide

    FUJITSU LIMITED • The contents of this manual may be revised without prior notice. • Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. • No part of this manual may be reproduced in any form without the prior written...

Table of Contents