Emptying And Cleaning The Inside Of The Boiler Tank; Troubleshooting - Kenwood Ariete SC 7.30 Instructions For Use Manual

Table of Contents

Advertisement

then turn the appliance over to empty the detergent container and remove the remaining water.

Emptying and cleaning the inside of the boiler tank

IMPORTANT: Clean the boiler tank at least once every month so as to remove any scale residues which
might affect the normal operation of the appliance.
IMPORTANT: Switch off the appliance, unplug it from the mains power and leave it to cool before cleaning
out the boiler tank, so as to avoid the risk of scalds.
Take out the water tank (P) and unscrew the cap (S) on the back of the appliance (
Slowly add tap water to the boiler tank to prevent any spurts of steam; shake the appliance and turn it upside down to
empty it. Repeat the operation several times.
WARNING: Never add scale removers, vinegar or other perfumed substances to the tank, as these risk
damaging the appliance with immediate cancellation of the warranty.
Tighten the cap (S) and refit the water tank (P).
PROBLEM
No steam comes out of the
nozzle
The nozzle is
dispensing little steam
No detergent is being
dispensed from the nozzle

TROUBLESHOOTING...

CHECK
Steam ready light (M)
off
Steam regulation dial (O) at
minimum
POSSIBLE CAUSES
Cold boiler tank
Lack of water in the tank (P)
or badly inserted tank (P)
Lack of pressure
Cold boiler tank
First-time use
No detergent in the reser-
voir
No apparent
cause
- 9 -
IT
).
16
POSSIBLE REMEDY
Wait for the steam ready
light to switch on (M)
Refill the water tank (P) as
described in the paragraph
"FILLING THE WATER
TANK DURING USE" and
make sure it is in the cor-
rect position
Adjust steam
dispensing
Wait for the steam ready
light (M) to switch on
Carry out the
procedures descri-
bed in the paragraph
"INSTRUCTIONS FOR
USE"
Fill the reservoir
Contact the ASSISTANCE
CENTRE
EN