Gas Conversions; Lp Gas Conversion - KitchenAid 30" (76.2 CM) COMMERCIAL STYLE DUAL FUEL CONVECTION RANGE Installation Instructions Manual

30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) commercial style dual fuel convection range
Hide thumbs Also See for 30" (76.2 CM) COMMERCIAL STYLE DUAL FUEL CONVECTION RANGE:
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT: Gas conversions from Natural gas to LP gas must
be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.

GAS CONVERSIONS

1. Turn the manual shutoff valve to the closed position.
2. Unplug range or disconnect power.

LP Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
B
C
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents