Error Code
Message Information
TMP0130
Message
LCD Message
Details
Action
TMP0132
Message
LCD Message
Details
Action
TMP0134
Message
LCD Message
Details
Action
VLT0100
Message
LCD Message
Details
Action
VLT0101
Message
LCD Message
138
The control panel temperature is less than the lower warning
threshold.
Control panel temperature is outside of range.
Ambient air temperature is too cool.
Check the system operating environment.
The control panel temperature is greater than the upper warning
threshold.
Control panel temperature is outside of range.
Ambient air temperature is too warm or one or more fans may have
failed.
Check the system operating environment and review event log for fan
failures.
The control panel temperature is outside of the allowable range.
Control panel temperature is outside of range.
Ambient air temperature is too warm or cool.
Check the system operating environment and review event log for fan
failures.
name > voltage is less than the lower warning
Processor module <
threshold.
name > voltage is outside of range.
Processor module <
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
3. If the issue persists, see
name > voltage is less than the lower critical
Processor module <
threshold.
name > voltage is outside of range.
Processor module <
Getting
Help.