6. V-COM Adjustment (PD-124 board)

Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
A4
Specified Value
The brightness difference between the
section A and section B is minimum.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: A4, change the data so that the
brightness of the section A and that of the section B is equal.
(The data of address: A4 should be "00" to "3F".)
Note: The V-COM adjustment mode is set up automatically, so the V
COM adjustment signal is displayed on the LCD screen.
3) Press the PAUSE button of the adjustment remote commander.
4) Select page: D, address: A4, substract 1 (TRV20E) or 3 (TRV6/
TRV6E) from the data, and press the PAUSE button.
5) Select page: 0, address: 01, and set data: 00.
B
A
B
A
Fig. 5-1-25.
A
B
A
B
5-42

7. White Balance Adjustment (PD-124 board)

Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
A8, A9
Specified Value
The LCD screen should not be colored.
Note: Check the white balance only when replacing the following parts. If
necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC3101
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: A8 and A9, set the data to the initial
value.
Note: To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
Address
A8
Data
8A
3) Check that the LCD screen is not colored. If colored, change
the data of page: D, address: A8 and A9 so that the LCD screen
is not colored.
Note: To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
When address: A8 or A9 is selected, the white balance
adjustment mode is set up automatically.
4) Select page: 0, address: 01, and set data: 00.
A9