D-Link DXS-3600 Series Reference Manual

Web ui reference guide layer 2/3 managed 10gbe switch
Hide thumbs Also See for DXS-3600 Series:

Advertisement

Web UI Reference Guide
Product Model: DXS-3600 Series
Layer 2/3 Managed 10GbE Switch
Release: 1.10

Advertisement

Table of Contents
loading

Summary of Contents for D-Link DXS-3600 Series

  • Page 1 Web UI Reference Guide Product Model: DXS-3600 Series Layer 2/3 Managed 10GbE Switch Release: 1.10...
  • Page 2 Information in this document is subject to change without notice. Reproduction of this document in any manner, without the written permission of the D-Link Corporation, is strictly forbidden. Trademarks used in this text: D-Link and the D-Link logo are trademarks of the D-Link Corporation; Microsoft and Windows are registered trademarks of the Microsoft Corporation.
  • Page 3: Intended Readers

    The DXS-3600 Series Web UI Reference Guide contains detailed information about the Web User Interface of the switch in this series. This manual is intended for advanced level users that are familiar with network management concepts and terminology. For all practical reasons the DXS-3600 Series will simply be referred to as the switch throughout this manual.
  • Page 4: Safety Cautions

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Safety Cautions To greatly reduce the risk of physical injury, electrical shock, fire, and damage to equipment, observe the following precautions. Observe and follow service markings. • Do not attempt to service any product, except when it is explained in the system’s documentation.
  • Page 5: General Precautions For Rack-Mountable Products

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide • 115V/60Hz is used mostly in North and South America as well as Far Eastern countries like as South Korea and Taiwan • 100V/50Hz is used mostly in Eastern Japan and 100V/60Hz in Western Japan •...
  • Page 6: Table Of Contents

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Table of Contents Intended Readers ............... . ii Typographical Conventions.
  • Page 7: Web-Based Switch Configuration

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Web-based Switch Configuration Management Options Connecting using the Web User Interface Management Options This switch provides multiple access platforms that can be used to configure, manage and monitor networking features available on this switch.
  • Page 8: Areas Of The User Interface

    NOTE: To be able to connect to the Web User Interface, a user account must be created first using the Command Line Interface. By default, there are no user accounts configured on this switch. See the DXS-3600 Series CLI Reference Guide for more information about creating user accounts by means of the Command Line Interface.
  • Page 9 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide AREA 2 AREA 1 Figure 2-3 Main Web Manager window On this page we will find three main areas to observe. Area Number Function AREA 1 This area displays graphical, real-time images of some of the hardware features run- ning on this switch.
  • Page 10: Switch Status

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Switch Status Device Information Temperature Status CPU Status System Log Entries Fan Status Flash, SD Card, and Memory Status After clicking on the Switch Status link, found in the menu, the following page will be displayed:...
  • Page 11: Device Information

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Device Information In the Device Information section, the user can view a list of basic information regarding the switch. In the Device Information section, the following display parameters are available:...
  • Page 12: Temperature Status

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Temperature Status In the Temperature section, the user can view a real-time display of the switch’s internal temperature. The temperature of the switch is mainly influenced by two factors: (1) the enviroment, and (2) the internal air-flow of the switch. In the Hardware Installation Guide, there are some guidelines that can assist the user with the installation of this switch in a temperature friendly environment.
  • Page 13: Cpu Status

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide CPU Status In the CPU section, the user can view a real-time display of the switch’s CPU usage. There are a number of factors that can influance a depleted CPU usage. One of those factors are network broadcasts. In the CLI Reference Guide there is an abundance of features that can be enabled to prevent this problem from occuring.
  • Page 14: System Log Entries

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide System Log Entries In the System Log section, the user can view a list of System log entries, generated by the switch, when certain events have occured. In the System Log section, the following display parameters are available:...
  • Page 15 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide...
  • Page 16: Fan Status

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Fan Status In the Fan section, the user can view a real-time display of the switch’s fan(s) status. A maximum of 3 fans can be installed in this switch. In this real-time graphic, we observe the status and speed of the three fans installed.
  • Page 17: Flash, Sd Card, And Memory Status

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Flash, SD Card, and Memory Status In this section, the user can view a real-time graphic that represents the memory usage for the Flash, SD Card, and RAM Memory. In this section, the following display parameters are available:...
  • Page 18: Traffic Monitoring

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Traffic Monitoring Traffic Monitoring by Direction Traffic Monitoring by Type Traffic Monitoring by Size Traffic Monitoring by Error After clicking on the Traffic Monitoring link, found in the menu, the following pages will be displayed.
  • Page 19: Traffic Monitoring By Type

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Traffic Monitoring by Type This page can be used to monitor traffic, per-port, of a certain type. After selecting a Port number and then selecting the Type option, from the drop-down menu, click the Apply button to...
  • Page 20: Traffic Monitoring By Size

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Traffic Monitoring by Size This page can be used to monitor traffic, per-port, of a certain packet size. After selecting a Port number and then selecting the Size option, from the drop-down menu, click the Apply button to...
  • Page 21: Traffic Monitoring By Error

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Traffic Monitoring by Error This page can be used to monitor traffic, per-port, of a certain error type and direction. After selecting a Port number and then selecting the Error option, from the drop-down menu, click the Apply button to...
  • Page 22: Management

    Also from time to time, D-Link provides new features that can only be acquired with a new firmware update. Keeping a copy of the configuration file ensures the convenience of not having to reconfigure the switch if it needs to be replaced.
  • Page 23: Download Configuration

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide The following parameters can be configured in this section: Parameter Description Destination File Enter the location and name of the Destination File. Source File Enter the location and name of the Source File or click the Browse button to navigate to the firmware file for the download.
  • Page 24 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Click the Upload button to initiate the upload.
  • Page 25: Appendix A - Password Recovery Procedure

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Appendix A - Password Recovery Procedure This section describes the procedure for resetting passwords on the D-Link DXS-3600 Series switch. Authenticating any user who tries to access networks is necessary and important. The basic authentication method used to accept qualified users is through a local login, utilizing a Username and Password.
  • Page 26: Appendix B - System Log Entries

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Appendix B - System Log Entries The following table lists all possible entries and their corresponding meanings that will appear in the System Log of this Switch. Category Log Description...
  • Page 27 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Configuration successfully downloaded. Informational Log Message: [TFTP(5):]Configuration successfully downloaded by <session> (Username: <username>, IP: <ipaddr>, MAC: <macaddr>) Parameters description: session: The user’s session.
  • Page 28 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note DNS Resolver Event description: Duplicate Domain name cache added. This will lead to Informational the dynamic domain name cache being deleted Log Message: [DNS_RESOLVER(1):]Duplicate Domain name case name: <domainname>, static IP: <ipaddr>, dynamic IP:<ipaddr>...
  • Page 29 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note 802.1X Event description: 802.1X Authentication failure. Warning Log Message: 802.1X Authentication failure [for <reason> ] from (Username: <username>, <interface-id>, MAC: <macaddr> ) Parameters description: reason: The reason for the failed authentication.
  • Page 30 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: The 802.1p default priority assigned from the RADIUS Informational server after the RADIUS client was successfully authenticated by the RADIUS server. This 802.1p default priority will be assigned to the port.
  • Page 31 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Conflict LLDP-MED device type detected. Notice Log Message: Conflict LLDP-MED device type detected (on port < portNum >, chassis id: < chassisType>, <chassisID>, port id: < portType>, <portID>, device class: <deviceClass>)
  • Page 32 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: The BGP FSM with Peer has gone to the successfully Informational established state. Log Message: [BGP(1):] BGP connection was successfully established (Peer:<ipaddr>). Parameters description: ipaddr: The IP address of the BGP peer.
  • Page 33 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: The number of BGP prefixes received from the neighbor Warning reached the threshold. Log Message: [BGP(8):] The number of prefixes received reached <num>, max <limit>...
  • Page 34 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note OSPFv2 Event description: OSPF interface link state changed. Informational Log Message: OSPF interface <intf-name> changed state to [Up | Down] Parameters description: intf-name: The name of the OSPF interface.
  • Page 35 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: One OSPF neighbor state changed from Loading to Full. Notice Log Message: OSPF nbr <nbr-id> on interface <intf-name> changed state from Loading to Full.
  • Page 36 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: One virtual router’s state becomes Initiate. Informational Log Message: VR <vr-id> at interface <intf-name> switched to Init Parameters description: vr-id: The VRRP virtual router ID.
  • Page 37 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: A virtual MAC address was added into the switch’s L3 Notice table. Log Message: Added a virtual IP <vrrp-ip-addr> MAC <vrrp-mac-addr> into the switch’s L3 table.
  • Page 38 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Failed when adding a virtual MAC into the switch’s L3 Error table. The box where the MAC was learned from is invalid. Log Message: Failed to add virtual IP <vrrp-ip-addr> MAC <vrrp-mac-addr>...
  • Page 39 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Port Security Event description: Port security violation. Warning Log Message: Port security violation. (MAC address: <macaddr> on <interface-id>) Parameters description: macaddr: The violation MAC address.
  • Page 40 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Successful Enable Admin authenticated by AAA local or Informational none or server. Log Message: Successful Enable Admin through <Console | TELNET | Web(SSL) | SSH> from <ipaddr > authenticated by AAA <local | none | server <ipaddr>>...
  • Page 41 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Broadcast storm cleared. Informational Log Message: <interface-id> Broadcast storm has cleared. Parameters description: interface-id: The interface name. Event description: Multicast storm occurrence. Warning Log Message: <interface-id>...
  • Page 42 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Spanning Tree port status changed. Notice Log Message: Spanning Tree port status changed [( [Instance:<InstanceID> ], port:< portNum>)] <old_status> -> <new_status> Parameters description: InstanceID: The instance ID.
  • Page 43 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Module Event Description: Module inserted and working. Informational Log Message: Module <module-type> is inserted. Parameters Description: module-type: The expansion module name. Event Description: Module inserted and not working.
  • Page 44 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Temperature sensor enters alarm state. Warning Log Message: Temperature sensor <sensorID> enters alarm state (current temperature: <temperature>) Parameters description: sensorID: The sensor ID.
  • Page 45 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note VPLS Event description: VPLS link up. Informational Log Message: VPLS <vpls_name> link up. Parameters description: vpls_name: The name of the link up VPLS. Event description: VPLS link down.
  • Page 46: Appendix C - Trap Entries

    DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Appendix C - Trap Entries This table lists the trap logs found on the Switch. Category Trap Name Description VRRP vrrpTrapNewMaster The newMaster trap indicates that the 1.3.6.1.2.1.68.0.1 sending agent has transitioned to 'Master' state.
  • Page 47 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Trap Name Description Authentication authenticationFailure An authenticationFailure trap signifies 1.3.6.1.6.3.1.1.5.5 that the SNMPv2 entity, acting in an agent role, has received a protocol message that is not properly authenticated. While all...
  • Page 48 DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide Category Trap Name Description LACP linkUp A linkUp trap signifies that the SNMP 1.3.6.1.6.3.1.1.5.4 entity, acting in an agent role, has detected that the ifOperStatus object for one of its communication links left...

Table of Contents