Autoranging - Craftsman 82005 Owner's Manual

Autoranging industrial multimeter
Table of Contents

Advertisement

FREQUENCY SENSITIVITY (ELECTRICAL)
The frequency sensitivity is range dependent when the Hz
function is selected while in the voltage or current measuring
mode. Below are typical sensitivities for the "electrical"
measurement modes.
Range
( DC/AC )
4V
40V, 400V
1000V/1000V
400mA
10A
AUTORANGING/MANUAL RANGE SELECTION
When the meter is first turned on, it automatically goes into
Autoranging. This automatically selects the best range for
the measurements being made and is generally the best
mode for most measurements. For measurement situations
requiring that a range be manually selected, perform the
following:
1. Press the RANGE key. The "Auto" display indicator will
turn off.
2. Press the RANGE key to step through the available
ranges. Observe the decimal point and units displayed
until the preferred range is located.
3. To exit the Manual Ranging mode and return to
Autoranging, press and hold the RANGE key for 2
seconds.
Note: Manual ranging does not apply for the Capacitance
and Frequency functions or for the mV range.
Sensitivity
Frequency
bandwidth
≥1.5V rms
5Hz~10kHz
≥10V rms
5Hz~20kHz
≥20V rms
5Hz~200kHz
≥420V rms
50Hz~1kHz
≥45mA rms
5Hz~5kHz
≥4A rms
5Hz~1kHz
18