3 Installation

This section contains detailed instructions for installing an HP NetServer LH 3r
in certain models of Compaq rack enclosures.

Preparation

Before beginning the installation of the NetServer into the rack, you must prepare
the rack and the NetServer.
Determine the location at which the NetServer is to be installed in the rack
enclosure. Mark the bottom and top of this location on the rack columns. The HP
NetServer LH 3r measures 8 EIA units tall.

Marking the Installation Holes

You will mark two holes on each of the four columns to use for the bar nuts and
screws that hold the slide to the column.
When marking the holes, mark the outer surface of the column (see Figure 3-1);
on the front columns, this is the column surface facing forward; on the rear
columns, this is the surface facing rearward. Use tape or a marker pen to mark
the appropriate holes on each column.
To mark the slide mounting holes (refer to Figure 3-1):
1. Count up from the top of the unit below, marking the 20th and 22nd
holes.
2. Repeat for all four columns.
NOTE
Do not place nuts or screws in the holes, only mark them.
7