HP -UX B6941-90001 Administrator's Reference Manual page 413

Management server on hp-ux
Table of Contents

Advertisement

Table 10-4
1. Stop ITO agents, including
the control agent:
2. Check that all ITO agents
are stopped.
3. Check the list of agent
PIDs given by the opcagt
-status command. If any
PIDs are not stopped, use the
kill (1M) command. Do not
kill the ITO Kernel Message
Logger opckmsg if running
on the managed node.
4. Check that no ITO
processes are still registered
with the llbd or dced/rpcd
daemons.
5. Remove temporary ITO
files.
6. Restart ITO agents.
a. If the managed node is also the ITO management server, stop the
b. If the managed node is also the ITO management server, restart the
Clean-up and Restart of ITO Agents on HP-UX 10.x/11.x
Managed Nodes
Task
a
b
ITO user interfaces and manager services. To do this: 1. Check that
all ITO GUIs are terminated (ps -eaf | grep opcui). If they are
not, terminate them using the [File: Exit] or (Ctrl+E) functions on
any HP OpenView submap owned by ITO or use the kill(1) com-
mand. 2. Stop the server processes: ovstop opc ovoacomm
ITO user interfaces and manager services, too: ovstart opc
ovoacomm
Chapter 10
Tuning, Troubleshooting, Security, and Maintenance
Troubleshooting: Specific Problems
HP-UX 10.x and 11.x Managed Nodes
/opt/OV/bin/OpC/opcagt -kill
/opt/OV/bin/OpC/opcagt -status
ps -eaf | grep opc kill <proc_id>
/usr/sbin/ncs/lb_admin
/opt/dce/bin/rpccp or
/opt/dce/bin/dcecp
rm -f /var/opt/OV/tmp/OpC/*
/opt/OV/bin/OpC/opcagt -start
413

Advertisement

Table of Contents
loading

This manual is also suitable for:

Openview it

Table of Contents