Alarm Settings
1
ALARM SET setting
This lets you make alarm settings for the video
images from the various connected devices.
Click on a button from [CH1] to [CH4] to display
the ALARM SET screen for that channel. You
can then make various settings such as
selecting external alarms and motion delector.
2
ALARM REC USE
This function stops any motion that occurs
during alarm setting. After the alarm settings
have been made, change this setting to "USE"
so that alarms can be detected in accordance
with the settings.
3
ALARM OUT
This is used to make settings for a device such
as a buzzer that is connected to the ALARM
OUT terminal at the rear of the video server
when an alarm is input.
When "NC" (normal close) or "NO" (normal
open) is selected, the ALARM OUT MODE or
ALARM OUT TIME menu is displayed.
Available settings:
OFF: No alarm is output when an alarm is
received.
NC: Normal close (normally closed, but an
alarm is output when open).
NO: Normal open (normally open, but an
alarm is output when closed).
4
ALARM OUT MODE
This operation can be used to manually switch to
output to the ALARM OUT terminal regardless of
whether an alarm is being received or not. When
set to "ON", the REMOTE ALARM indicator
(black) is displayed in the initial screen. (p. 32)
English
5
ALARM OUT TIME
This sets the alarm duration when the external
alarm or motion detector detects an alarm.
The "REMOTE" setting only appears when
"ALARM OUT MODE" is set to "REMOTE
CONTROL". (p. 27)
Available settings:
2, 5, 10, 15, 20, 30, 60 sec.,
2, 3, 4, 5 min., REMOTE
6
ALARM SOUND MODE
This setting causes an alarm warning to sound
when an alarm is detected. If set to "USE",
"BEEP OFF" appears in the initial screen when
an alarm is detected at the same time as the
alarm buzzer sounds. If you click this indicator,
the alarm buzzer will stop.
7
ALARM BUFFERING SET
This is used to make settings related to
recording alarm images. The screen shown in
"ALARM BUFFERING SET Setting" (p. 28) will
be displayed for you to make detailed settings.
8
EXTERNAL ALARM
Select "NC" (normal close) or "NO" (normal
open) to display the external alarm setting menu.
Available settings:
OFF: No external alarm input is detected.
NC: Normal close (normally closed, but input
is detected when open).
NO: Normal open (normally open, but input
is detected when closed).
9
MOTION DETECTOR
When set to "ON", the MOTION DETECTOR
SET screen is displayed. Sensor marks (ú) are
used to set the detection area in this setting
screen.
F
MOTION DETECTOR LEVEL
This sets the sensitivity level for the sensor
marks (ú). See p. 32 for details on the sensitivity
level.
– 27 –