Sharp PN-K322B Operation Manual page 32

Lcd monitor
Hide thumbs Also See for PN-K322B:
Table of Contents

Advertisement

Controlling the Monitor with a PC (RS-232C)
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
ALL RESET
ADJUSTMENT LOCK
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
Others
Function
VOLUME
BRIGHT
TEMPERATURE SENSOR
TEMPERATURE ACQUISITION
CAUSE OF LAST STANDBY MODE
32
E
Command
Direction
Parameter
RSET
W
0
ALCK
WR
0-2
LOSD
WR
0-2
OFLD
WR
0-1
TALT
WR
0-2
SALT
WR
0-2
Command
Direction
Parameter
VOLM
WR
0-31
VLMP
WR
0-31
DSTA
R
ERRT
R
STCA
W
0
R
Reply
Control/Response contents
0-2 0: OFF, 1:ON 1, 2:ON 2
0-2 0: ON 1, 1: OFF, 2: ON 2
0-1 0: ON, 1: OFF
0-2 0: OFF, 1: OSD & LED, 2: LED
0-2 0: OFF, 1: OSD & LED, 2: LED
Reply
Control/Response contents
0-31
0-31
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in
standby mode
2 Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is
dimmed
4 Temperature sensor abnormal
Value Returns the temperature of the temperature sensor.
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
20 Standby mode by OFF IF NO OPERATION setting
*
-
-
-
-
-
-
*
-
-
-