Pressure Sensor (Water Level Switch) - GE Profile WPGT9150 Technical Service Manual

High-efficiency washer
Table of Contents

Advertisement

Pressure Sensor (Water Level Switch)

The pressure sensor is connected by a clear hose to
an air reservoir near the bottom of the outer tub and
operates by a frequency (kHz) signal to the inverter
board.
The pressure sensor wires (purple, orange, and blue)
are connected at pins 1, 3, and 4 at the 4-pin red
connector on the inverter board. (See
Main Board Pin Connectors
The approximate resistance value of the transducer,
measured between the purple and orange wires, is
20 Ω.
White
PRESSURE
S/W
White
When the water level rises in the washer tub,
air is trapped in the reservoir. As the water level
rises, the air pressure in the reservoir increases.
The pressure is translated into an electrical
signal (frequency) by the pressure sensor.
The frequency will vary from approximately
27 kHz (empty tub) to 22 kHz (full tub).
This frequency can be measured at the pressure
sensor between the purple and orange wires.
Inverter and
.)
Purple
Orange
Red
Dk. Blue
White
LID
S/W
The frequency is monitored by the inverter, which
turns off the water valves when the desired water
level is achieved.
Note: The water level will vary depending on the
load size, which is measured by the dry load and
wet load sensing cycles. This information is sent to
the inverter, which then determines the appropriate
water level. Minimum fi ll is 17.5 gallons, and
maximum fi ll is 27 gallons.
Pressure Sensor Test
If the pressure sensor is not operating correctly,
perform the following test:
1.
Set the wash cycle to SNEAKERS. This cycle
bypasses the load sensing feature and defaults
to the minimum water level.
2.
Measure the water level from the center hub of
the infusor (it should be approximately 2 inches
deep in the tub).
3.
Set the washer to
bypasses the load sensing feature and defaults
to the maximum water level.
4.
Measure the water level from the center hub of
the infusor (it should be approximately 11 inches
deep in the tub).
Note: Before disconnecting the hose from the
pressure sensor, be sure the water level is below the
bottom of the spin basket.