Main code
Main code
26
20
Rear edge void setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of rear edge void setting is displayed.
2. Enter the code number of rear edge void setting and press the START key, and the setting will be changed.
30
CE mark application control ON/OFF setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of CE mark application is displayed.
2. Enter the code number of CE mark application and press the START key, and the setting will be changed.
38
Drum life over stop cancel
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
39
Memory capacity setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
40
Polygon motor OFF time setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
42
Transfer ON timing control (Setting the time to transfer ON)
(Operation / Procedure)
1.When this simulation is executed, the currently set code number is displayed.
2.Enter the code number and press the START key, and the setting will be changed. (For any number different
from the following ones, the default time is automatically set.)
Code number
Rear edge void setting
0
Rear edge void allowed
1
Rear edge void not allowed
Code number
CE mark application setting
0
CE mark application control OFF
1
CE mark application control ON
Code number
0
Stop at drum life over
1
Stop cancel at drum life over
Code number
0
1
2
Code number
0
1
2
3
Code number
0
Default (330 msec)
1
2
3
4
5
Default (330 msec)
6
7
8
9
10-6
Contents
Setting
Setting
No memory
4Mbyte
6Mbyte
Setting
0 sec
30 sec
60 sec
90 sec
Setting
-40msec
-30msec
-20msec
-10msec
+10msec
+20msec
+30msec
+40msec
AL-1000/1010