2-2. Error Messages

2-3. Display Panel and Lamp Operation Check

2-2. Error Messages
The error message is superimposed on the viewfinder screen if any fault occurs during the power-on
sequence or normal operation.
Error message
Operation
STORED DATA:NG
Blinks on the viewfinder screen during the
power-on sequence
CAM?
Displayed during the power-on sequence or
normal operation
VTR?
Displayed during the power-on sequence or
normal operation
2-3. Display Panel and Lamp Operation Check
The display panel and all lamps can be checked for all on and all off using the VTR (DIAG) menu of the
unit.
Refer to Section "3-2. VTR (DIAG) menu" for details of the VTR (DIAG) menu. Perform the check as
follows.
1
Select the page DIAG-8 of the DIAG menu (VF screen : VTR MENU-12 page).
2
Check all on and all off of the display panel and the following lamps.
Every pressing of the SHIFT button toggles between all on and all off. It also toggles between the
messages "ALL OFF" and "ALL ON" on the VF screen.
. REW button
. F. FWD button
. PLAY button
. WARNING lamp (on side of display panel)
. Tally lamp (VF)
. Camera-man tally lamp (VF)
. Back tally lamp (VF)
. Rear tally lamp (rear panel)
. Green tally lamp (in VF)
. TALLY/REC lamp (in VF)
. BATT lamp (in VF)
. "!" (error status warning) lamp (in VF)
. Spare lamp (in VF)
. VTR SAVE lamp (in VF)
2-2
Remedy
The white and/or black balance memory data
have been lost. Adjust the white and black
balance again
A fault has been detected in the camera
Contact your local Sony Sales Office/
Service Center
A fault (HUMID or SLACK) has been detected
in the VTR
Check the warning indicators on the display
panel